User manual
ADPRO
®
XOa Client Software User Manual
21796_05_preliminary 129
Choose the PIR option. By default all parameters are attributed. There is no need to change any of the
settings.
Note
When using the USB to RS485 distribution unit or the USB to serial port RS485 converter, your
only option is to use the /dev/ttyU2 USB port.
When connecting your PIR directly to the Main I/O of the server (using an RS-485 cable), you
will have to use either the /dev/ttyU6 USB port (for the first Main I/O card) or the /dev/ttyU8 USB
port (for the second Main I/O card). These ports are automatically detected by the XOa client
software.
16.3.2 Initiating the PIR Discovery
Open the PIR settings window via System > Behaviour > PIR settings.
16.3.2.1 General
In this section you can set the walk test port. This port is used for the iPIR app. This app allows you to
configure your PIR settings and visualize PIR detections on a scope on your mobile device. For more
information, see the iPIR User Manual. For iPIR to work, you have to enable Technician access. See
Granting the Technician on page 140.
The default walk test port to use with iPIR is 5555.
16.3.2.2 Discovery and Status of the PIR Detectors
The Discovery and status of the PIR detectors panel displays the connected PIR devices and their status.
If the PIR devices are operating normally, a green circle appears for Config status. The circle turns yellow
when there is a problem with configuration of one of the PIR devices (for example if the serial port is not
configured correctly).