User manual

ADPRO
®
XOa Client Software User Manual
21796_05_preliminary 121
Parameter
Description
Default value
Destination
You can enter the parameters for 5 different computers that
will receive alarms. Click the number you would like to define
(or see).
Note
The alarm will only be sent to 1 IP address. Only
when no communication with the first IP address
can be established, the second IP address will be
used. If still no communication is possible, the
third, fourth, and fifth IP address will be used. If
none of the 5 defined IP addresses are available,
the backup transmission will be activated.
Alarm reception requires appropriate alarm management
software on the computer (e.g. VCP, EMS, or M3000).
IP address
Enter the IP address of the computer that will receive alarms.
0.0.0.0
IP port
Enter the IP port on which alarms must be transmitted.
10000
Telephone number
Enter the telephone number to which alarms must be
transmitted. This option is only available for a dial-up
network.
14.4 Setting up Parallel Transmission
Besides the transmission to the main CMS, you can set up parallel transmission to two more monitoring
stations.
To set up parallel transmission, proceed as follows:
1. Choose System > Behaviour > Alarm Transmission > Parallel Alarm Transmission.
2. To activate parallel transmission, select the check boxes for Parallel transmission 1 and/or 2.
3. Provide the required settings for each parallel transmission channel. Setup is similar to that of the
primary transmission. For more information, see General on page 118; and also Primary Alarm
Transmission Settings on page 119.