User manual

User Manual ADPRO
®
XOa Client Software
120 21796_05_preliminary
Parameter
Description
Default value
Destination
You can enter the parameters for 5 different computers that
will receive alarms. Click the number you would like to define
(or see).
Note
The alarm will only be sent to 1 IP address. Only
when no communication with the first IP address
can be established, the second IP address will be
used. If still no communication is possible, the
third, fourth, and fifth IP address will be used. If
none of the 5 defined IP addresses are available,
the backup transmission will be activated.
Alarm reception requires appropriate alarm management
software on the computer (e.g. VCP, EMS, or M3000).
IP address
Enter the IP address of the computer that will receive alarms.
0.0.0.0
IP port
Enter the IP port on which alarms must be transmitted.
10000
Telephone number
Enter the telephone number to which alarms must be
transmitted. This option is only available for a dial-up
network.
14.3 Secondary Alarm Transmission Settings
Parameter
Description
Default value
Line test
None;
Interval: this will send a life check message every x minutes.
To make sure this functions correctly, the message (I0035 –
[SYST] – Backup lifecheck) needs to be configured with a
correct alarm profile!
Also set the time on which the first alarm transmission
should be sent.
Note
For dial-up networks it is recommended to
execute the line test less frequently, because of
the connection cost (e.g. 1 test a day).
None
Auto-negotiate IP
address (PPP)
This option is only available for a dial-up network. When
ticked, IP addresses will be assigned by the CMS, during the
time of the communication. This option is required if the CMS
uses the Video Central Platinum software.
Not selected