User manual
User Manual ADPRO
®
XOa Client Software
116 21796_05_preliminary
Apply a filter to reduce the list.
Click Save to apply the new settings.
Note
Outputs that are already used for another operation cannot be modified here.
13.7.1 Manual Operation
Select the desired output and choose Manual operation.
The output will thus need to be switched by a user from the client software.
To allow the specific output to be activated from the Live Video window, select the cameras on which this
activate output button has to appear.
For more information, see Activating an Output Manually on page 149.
You also have to define which action needs to be taken when closing the client software application:
Reset output: the output always resets to idle state when closing the client application.
Latch output: the output remains in the selected state, even after closing the client application.
13.7.2 Recording Controlled
If you set an output to Recording controlled, that output can be activated when a recording is started. See
Cameras on page 67.
13.7.3 Programmable Output
This option activates an output in function of a condition or event. The condition is specified in the drop-down
list:
With the last option –Logic– you can define a specific condition, selecting particular inputs linked with AND
and OR functions. Brackets allow to modify the order of evaluation (which is normally from left to right). The
state of an input can be inverted (NOT function) and the isolate state of an alarm can be selected
(ISOLATE). Select an input from the list and click ADD (in the Tools section) to insert it at the current
position. On error, click DEL. To clear the whole line, click CLEAR.
Click the NOT button before adding an input if you want to invert its state.
Click the ISOLATE button just after adding an input if you want to read its operational state (isolated or not).
The letter M appears in front of the number of the selected input.