User manual
ADPRO
®
XOa Client Software User Manual
21796_05_preliminary 109
In entry/exit path
(value in seconds)
Tick this option if the alarm has to be delayed. The delay is specified by the
parameter ‘Entry/Exit hold time delay’.
On entry to the building, the video system has to be disarmed within this time to
prevent alarms on the delayed inputs. On exit, the building has to be abandoned
within this time counting from the moment when it is armed.
Modify the alarm parameters of the selected input and click Save to apply the new settings.
13.2 PTZ via I/O
It is possible to define PTZ preset positions via an input. Open the Input/Output behaviour window via
System > Behaviour > Input/Output behaviour.
Select the desired input and click Camera PTZ Presets.
You will get the following popup window:
All PTZ cameras can be provided with 1 specific PTZ preset. When an input is triggered, the camera will
move to the configured PTZ preset position. The alarm message will be delayed, however, until the PTZ
preset positioning time has expired. This is done to make sure no blurry images are recorded.
Note
It is not possible to define camera PTZ presets for system inputs, except for SYSTEM ARMED,
ENTRY ERROR, EXIT ERROR, GENERAL MODE 1–4, and FIRE SYSTEM FAULT.
13.3 Connecting Fire Detectors
You can connect up to 20 fire detectors to the server. These detectors can either be connected to real inputs
on the server or via Net I/O modules.
Open the Input/Output behaviour window via System > Behaviour > Input/Output Behaviour. Choose a
fire event profile and attribute a fire detector number.