12.4.4 Silent Message Profile
A silent message profile is defined to generate an alarm, but the alarm is not sent to any transmission
destination.
The alarm message is generated in both armed and disarmed state, but will not be sent to an alarm
management system (like M3000). The idea behind this type of alarm is to get an overview in the log file.
The profile type is 0 – Alarm (generic profile type). Note that you cannot modify the profile type of the
standard alarm profiles.
12.4.5 Single Event Profile
A single event profile is defined to send alarms for all detections to all transmission destinations. It does
not take the operational state into account: the alarm will be generated in both armed and disarmed state.
When the end of alarm is detected, a new alarm message will be sent to indicate that the alarm is no longer
sustained. The alarm will, however, not be repeated every 15 minutes as long as the alarm is sustained.
The profile type is 0 – Alarm (generic profile type). Note that you cannot modify the profile type of the
standard alarm profiles.