User manual
User Manual ADPRO
®
XOa Client Software
100 21796_05_preliminary
To modify the behaviour of alarm transmission of inputs, you need to modify the associated alarm profile of
the input. It is however not recommended to modify the default alarm profiles. It is better to create a new
alarm profile with different settings. See Adding a New Profile on page 97.
12.4.1 Normal Event Profile
A normal event profile is defined to send alarms for all detections to all transmission destinations: primary,
backup, parallel, and email. It does not take the operational state into account: the alarm will be generated in
both armed and disarmed state. Furthermore, the alarm transmission will be repeated every 15 minutes as
long as the alarm is sustained. When the end of alarm is detected, a new alarm message will be sent to
indicate that the alarm is no longer sustained.
The profile type is 0 – Alarm (generic profile type). Note that you cannot modify the profile type of the
standard alarm profiles.
12.4.2 Primary Event Profile
A primary event profile is defined to send alarms for all detections to the primary transmission destination,
but not the backup transmission. It also sends to the parallel and email transmission destinations. It does
not take the operational state into account: the alarm will be generated in both armed and disarmed state.
Furthermore, the alarm transmission will be repeated every 15 minutes as long as the alarm is sustained.
When the end of alarm is detected, a new alarm message will be sent to indicate that the alarm is no longer
sustained.
The profile type is 0 – Alarm (generic profile type). Note that you cannot modify the profile type of the
standard alarm profiles.