Service manual
27
P50T01U/E P50TP01U/E P42T01U/E P42TP01U/E
Digital module self-diagnosis function
At main microcomputer startup, hardware (mainly LSI) is checked by a self diagnosis program.
To enter this Self-Diagnosis mode, follow the following steps:
Procedure:
1) Enter Adjustment Mode.
2) Select SELF TEST and press OK button.
3) SELF TEST screen is displayed.
4) Each code is displayed in a SELF TEST screen.
A diagnosis result is displayed with a numerical value to the right side of each code.
Numerical value of 0 indicates normal, all values except 0 are errors.
PDP ADJUST MODE
OPTION
MAINTENANCE
SELF TEST
LINE MODE
MMC DEMO
MEMORY INIT
SELF TEST
SELF TEST
ddb :0
dsm :0
dle :0
dfl :0
dmp :0
ddm :0
dcd :0
drm :0
dpci :0
dlan :0
dsi :0
0 :OK
others :NG
OK
Return
Adjustment Mode screen
SELF TEST screen
A list of codes
code function circuit No. PCB name Error contents
ddb Debug I101 MAIN parameter error, system error
dsm Sub-microcomputer IH04 MAIN system error (-1)
dle LED IH04 MAIN seine general-purpose port lead error, lighting time error, system error
dfl flash I103 MAIN parameter error, device error, system error
dmp MPEG I101 MAIN Video error (2), Audio error (4)
ddm demulti - - error
drm key scan IH04 MAIN system error (-1) / others error (3)
dic IICbus driver I101 MAIN R_SYS_ERROR(-1), DIC_R_DEVICE_ERROR(2)
dvad ADC I101 MAIN system error (-1) /device (I2C) error (2) / driver error (6)
dfc FC I101 MAIN firmware error code, system error
dhdm HDMI I102 MAIN system error (-1) / parameter error (1) / device (I2C) error (2)
dvdc Video decoder I102 MAIN device error, system error
dpdp PDPpanel (for PDP) - PDP panel system error
dldp LCDpanel (for LCD) - LCD panel state impossible of command acceptance, standby, parameter error
dvi Video I101 MAIN device error(firmware error), system error
dvbi VBI slicer I102 MAIN system error
dsl Video Switch I101 MAIN system error
dada Audio amplifier IF07 MAIN parameter error, setting error in suspend, system error
I2C communication error with TAS3103 or TAS5508
dau Audio I101 MAIN system error
dhpa Headphones amplifier I003 SUB standby, state error
dtu Digital / Analog tuner UT01,UT02 Terminal fail in initialisation, system error
dswv Swivel IH04 MAIN system error (-1) / parameter error (1) /
sub-microcomputer driver communication error (2) /
initialisation registration not possible error (4)
dmmc MMC - - driver initialisation error, system error
dptp PTP driver I101 MAIN R_SYS_ERROR (-1) other errors (10)
dpq Picture control driver I102, IM01 MAIN,SUB parameter error, system error, suspend error, device error
ddp Display driver I101 MAIN system error
dttc Analog TeleText IR01 SUB device error, system error
dpyc PAL3DY/C Video decoder IM01 SUB device error, system error
dsp Multiplex driver IY01 SUB system error (-1) / I2C communication error (2)