Installation Guide

5.8GHz All Weather 8 Channel Series Manual Rev. E
damage, not covered under manufacturer warranty.
Power Supply Connection
Inside the enclosure you will find a green
terminal strip with orange terminal lock tabs.
WARNING! Transformer must not be
powered while making connections to the
terminal strip. An electrical short can occur,
causing harmful damage to the unit.
Turn the small cable gland counter clock
wise to loosen. Use a Metric 15mm
wrench. (Closest Imperial Size 5/8”)
Feed the power cable wire through the
cable gland hole.
Push down the orange lock tabs to open
the terminal input. Insert negative (-)
and positive (+) wire leads as illustrated. See
Figure 5 Release the orange terminal lock tab.
Ensure the wire is locked tight into the terminal
to avoid an electrical short.
Re-tighten the cable gland and ensure water
tight seal
POSITIVE ( + ) 9 14VDC INPUT
NEGATIVE ( - ) 9 14 VDC INPUT
IMPORTANT! Failure to tighten the
cable gland may result in water damage,
not covered under manufacturer warranty.