Product Card

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | E-mail: sales@victronenergy.com
www.victronenergy.com
Orion-Tr Smart Chargers Isolated
220 - 280 Watt
12/12-18
(220W)
12/24-10
(240W)
24/12-20
(240W)
24/24-12
(280W)
Input voltage range (1) 8-17V 8-17V 16-35V 16-35V
Under voltage shut down
7V
14V
Under voltage restart
7,5V
15V
Nominal output voltage
12,2V
24,2V
Output voltage adjust range 10-15V 20-30V 10-15V 20-30V
Output voltage tolerance +/- 0,2V
Output noise
2mV rms
Cont. output current at nominal
output voltage and 40°C
18A 10A 20A 12A
Maximum output current (10 s)
at nominal output voltage
25A 15A 25A 15A
Short circuit output current 40A 25A 50A 30A
Cont. output power at 25°C
280W 280W 300W 320W
Cont. output power at 40°C 220W 240W 240W 280W
Efficiency 87% 88% 88% 89%
No load input current
< 80mA
< 80mA
Standby current
Less than 1mA
Galvanic isolation
200V dc between input, output and case
Operating temperature range -20 to +55°C (derate 3% per °C above 40°C)
Humidity
Max. 95% non-condensing
DC connection
Screw terminals
Maximum cable cross-section 16 mm² AWG6
Weight
1,3 kg (3 lb)
Dimensions hxwxd 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)
Standards: Safety
Emission
Immunity
Automotive Directive
EN 60950
EN 61000-6-3, EN 55014-1
EN 61000-6-2, EN 61000-6-1, EN 55014-2
ECE R10-5
Orion-Tr Smart Chargers Isolated
360 - 400 Watt
12/12-30
(360W)
12/24-15
(360W)
24/12-30
(360W)
24/24-17
(400W)
Input voltage range (1) 10-17V 10-17V 20-35V 20-35V
Under voltage shut down 7V 7V 14V 14V
Under voltage restart
7,5V
7,5V
15V
15V
Nominal output voltage
12,2V
24,2V
12,2V
24,2V
Output voltage adjust range
10-15V
20-30V
10-15V
20-30V
Output voltage tolerance +/- 0,2V
Output noise 2mV rms
Cont. output current at nominal output
voltage and 40°C
30A 15A 30A 17A
Maximum output current (10 s) at
nominal output voltage minus 20%
40A 25A 45A 25A
Short circuit output current
60A
40A
60A
40A
Cont. output power at 25°C
430W 430W 430W 480W
Cont. output power at 40°C
360W 360W 360W 400W
Efficiency 87% 88% 88% 89%
No load input current < 80mA < 100mA < 100mA < 80mA
Standby current
Less than 1mA
Galvanic isolation 200V dc between input, output and case
Operating temperature range
-20 to +55°C (derate 3% per °C above 40°C)
Humidity
Max. 95% non-condensing
DC connection Screw terminals
Maximum cable cross-section 16 mm² (AWG6)
Weight 12V input and/or 12V output models: 1,8 kg (3 lb) Other models: 1,6 kg (3.5 lb)
Dimensions hxwxd
12V input and/or 12V output models: 130 x 186 x 80 mm (5.1 x 7.3 x 3.2 inch)
Other models: 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)
Standards: Safety
Emission
Immunity
Automotive Directive
EN 60950
EN 61000-6-3, EN 55014-1
EN 61000-6-2, EN 61000-6-1, EN 55014-2
ECE R10-5
1) If set to nominal or lower than nominal, the output voltage will remain stable within the specified input voltage range (buck-boost function). If the
output voltage is set higher than nominal by a certain percentage, the minimum input voltage at which the output voltage remains stable (does
not decrease) increases by the same percentage.
Note 1) The VictronConnect App will not display current in or current out.
Note 2) The Orion-Tr Smart is not equipped with a VE.Direct port.