6
Main display. It shows battery voltage, battery capacity,
charging and discharging status.
Press MENU to enter next display.
Change Settings Main
display. press on the
MENU key for
several seconds until
the numbers flash, you
are in:
Battery type setting.
See table below.
The factory setting is b01
*The controllers do not have a remote on/off input. Therefore use LiFePO4 batteries with integrated BMS
only (such as the Victron SuperPack batteries)
NA for 48V
press on the MENU
key again and you are
in:
Low voltage disconnect
The factory setting is 11.2V
[22.4V] 44.8V
press on the MENU
key again and you are
in:
Low voltage reconnect
The factory setting is 12.6V
[25.2V] 50.4V
Solar Voltage display. It shows Solar Panel voltage,
battery capacity status.
Press MENU to enter next display.
Battery type
Battery
voltage
Absorbti
on
voltage
Float
voltage
Low voltage
disconnect
factory
setting
Low voltage
disconnect
range
Low voltage
reconnect
factory setting
Low voltage
reconnect range
b01
LEAD-ACID
[AGM]
12.0V [24V]
48V
14.4V
[28.8V]
57.6V
13.7V
[27.4V]
54.8V
11.2V [22.4V]
44.8V
10.5V-12.0V
in steps of
0.1V
12.6V [25.2V]
50.4V
12.0V-13.5V in
steps of 0.1V
b02
LEAD-ACID
[Gel]
12.0V [24V]
48V
14.2V
[28.4V]
56.8V
13.7V
[27.4V]
54.8V
11.2V [22.4V]
44.8V
10.5V-12.0V
in steps of
0.1V
12.6V [25.2V]
50.4V
12.0V-13.5V in
steps of 0.1V
b03
LEAD-ACID
[Wet]
12.0V [24V]
48V
14.6V
[29.2V]
58.4V
13.7V
[27.4V]
54.8V
11.2V [22.4V]
44.8V
10.5V-12.0V
in steps of
0.1V
12.6V [25.2V]
50.4V
12.0V-13.5V in
steps of 0.1V
b04*
12V
LiFePO4
12.8V
14.2V
13.35V
11.2V
10.5V-12.0V
in steps of
0.1V
12.6V
12.0V-13.5V in
steps of 0.1V
b05*
24V
LiFePO4
25.6V
28.4V
26.7V
22.4V
21.0V-24.0V
in steps of
0.1V
25.2V
24.0V-27.0V in