Product Card

Ultra-fast Maximum Power Point Tracking (MPPT)
Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT
controller will improve energy harvest by up to 30% compared to PWM charge controllers and by up to 10%
compared to slower MPPT controllers.
Load output
Over-discharge of the battery can be prevented by connecting all loads to the load output. The load output
will disconnect the load when the battery has been discharged to a pre-set voltage.
Alternatively, an intelligent battery management algorithm can be chosen: see Battery Life.
The load output is short circuit proof.
Some loads (especially inverters) can best be connected directly to the battery, and the inverter remote
control connected to the load output. A special interface cable may be needed, please see the manual.
Battery Life: intelligent battery management
When a solar charge controller is not able to recharge the battery to its full capacity within one day, the
result is often that the battery will continually be cycled between a ‘partially charged’ state and the ‘end of
discharge’ state. This mode of operation (no regular full recharge) will destroy a lead-acid battery within
weeks or months.
The Battery Life algorithm will monitor the state of charge of the battery and, if needed, day by day slightly
increase the load disconnect level (i.e. disconnect the load earlier) until the harvested solar energy is
sufficient to recharge the battery to nearly the full 100%. From that point onwards the load disconnect level
will be modulated so that a nearly 100% recharge is achieved about once every week.
Programmable battery charge algorithm
See the software section on our website for details
Day/night timing and light dimming option
See the software section on our website for details
Programming, real-time data and history display options
- Color Control GX or other GX devices: see the
Venus
documents on our website.
- A smartphone or other Bluetooth-enabled device: VE.Direct Bluetooth Smart dongle needed.
BlueSolar Charge Controllers MPPT 75/10, 75/15 & MPPT 100/15
Solar Charge Controller
MPPT 75/15
BlueSolar Charge Controller MPPT 75/10 MPPT 75/15 MPPT 100/15
Battery voltage 12/24V Auto Select
Rated charge current 10A 15A 15A
Nominal PV power, 12V 1a,b) 145W 220W 220W
Nominal PV power, 24V 1a,b) 290W 440W 440W
Max. PV short circuit current 2) 10A 15A 15A
Automatic load disconnect Yes, maximum load 15A
Maximum PV open circuit voltage 75V 100V
Peak efficiency 98%
Self-consumption 12V: 20 mA 24V: 10 mA
Charge voltage 'absorption' 14,4V / 28,8V (adjustable)
Charge voltage 'float' 13,8V / 27,6V (adjustable)
Charge algorithm multi-stage adaptive
Temperature compensation -16 mV / °C resp. -32 mV / °C
Continuous/peak load current 15A / 50A
Low voltage load disconnect
11,1V / 22,2V or 11,8V / 23,6V
or Battery Life algorithm
Low voltage load reconnect
13,1V / 26,2V or 14V / 28V
or Battery Life algorithm
Protection
Battery reverse polarity (fuse)
Output short circuit / Over temperature
Operating temperature -30 to +60°C (full rated output up to 40°C)
Humidity 95%, non-condensing
Data communication port
VE.Direct
See the data communication white paper on our website
ENCLOSURE
Colour Blue (RAL 5012)
Power terminals 6 mm² / AWG10
Protection category
IP43 (electronic components),
IP22 (connection area)
Weight 0,5 kg
Dimensions (h x w x d) 100 x 113 x 40 mm
STANDARDS
Safety EN/IEC 62109-1, UL 1741, CSA C22.2
1a) If more PV power is connected, the controller will limit input power.
1b) PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter minimum PV voltage is Vbat + 1V
2) A PV array with a higher short circuit current may damage the controller.
VE.Direct Bluetooth Smart
dongle needed to enable
Bluetooth

Summary of content (1 pages)