Product Manual
8
8. Battery related programming options
(see software manual or remote panel manual for details)
Battery related programming
options
Gel
Sealed
(default
setting)
Flooded
User
defined
Battery capacity setting (needed
for the internal battery monitor)
200Ah 1~9999
Over voltage load disconnect
16.0V
9~17V
Charge limit
15.0V
9~17V
Over voltage reconnect
15.0V
9~17V
Equalize
——
14.6V
14.8V
9~17V
Absorption
14.2V
14.4V
14.6V
9~17V
Float
13.8V
13.8V
13.8V
9~17V
New charge cycle trigger voltage
13.2V
9~17V
Low voltage load reconnect
12.6V
9~17V
Under voltage warning reset
12.2V
9~17V
Under voltage warning
12.0V
9~17V
Low voltage load disconnect
11.1V
9~17V
Discharge limit
10.6V
9~17V
Equalize duration
——
2 hrs.
2 hrs.
0~3
Absorption duration
2 hrs.
2 hrs.
2 hrs.
0~3
Multiply voltages by 2 for a 24V system
9. Day/night timing options (see software manual or remote
panel manual)