Product Card

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | E-mail: sales@victronenergy.com
www.victronenergy.com
Orion-Tr Smart Chargers
non-isolated
360 - 400 Watt
12/12-30
(360W)
12/24-15
(360W)
24/12-30
(360W)
24/24-17
(400W)
Input voltage range (1) 10-17V 10-17V 20-35V 20-35V
Under voltage shut down 7V 7V 14V 14V
Under voltage restart 7,5V 7,5V 15V 15V
Nominal output voltage 12,2V 24,2V 12,2V 24,2V
Output voltage adjust range
10-15V
20-30V
Output voltage tolerance +/- 0,2V
Output noise 2mV rms
Cont. output current at nominal
output voltage and 40°C
30A 15A 30A 17A
Maximum output current (10 s)
at nominal output voltage
40A 25A 45A 25A
Short circuit output current
60A
40A
Cont. output power at 25°C 430W 430W 430W 480W
Cont. output power at 40°C 360W 360W 360W 400W
Efficiency 87% 88% 88% 89%
No load input current < 80mA < 100mA < 100mA < 80mA
Standby current
Less than 1mA
Operating temperature range
-20 to +55°C (derate 3% per °C above 40°C)
Humidity
Max. 95% non-condensing
DC connection Screw terminals
Maximum cable cross-section 16 mm² (AWG6)
Weight 12V input and/or 12V output models: 1,8 kg (3 lb) Other models: 1,6 kg (3.5 lb)
Dimensions hxwxd
130 x 186 x 80 mm (5.1 x 7.3 x 3.2 inch)
Standards: Safety
Emission
Immunity
Automotive Directive
EN 60950
EN 61000-6-3, EN 55014-1
EN 61000-6-2, EN 61000-6-1, EN 55014-2
ECE R10-5
1) If set to nominal or lower than nominal, the output voltage will remain stable within the specified input voltage range (buck-boost function). If the
output voltage is set higher than nominal by a certain percentage, the minimum input voltage at which the output voltage remains stable (does
not decrease) increases by the same percentage.
Note 1: The VictronConnect App will not display current in or current out.
Note 2: The Orion-Tr Smart is not equipped with a VE.Direct port.