Product Manual

20
5.5.3 Exemplary settings
Example 1 is the factory setting (since factory settings are entered by computer, all DIP
switches of a new product are set to ‘off’, except for DS-2).
DS-1 Panel option
off
DS-2 Panel option
on
DS-3 Ch. voltage
off
DS-4 Ch. voltage
off
DS-5 Frequency
off
DS-6 Search mode
off
DS-7 AC-in Limit
off
DS-8 Store setting
DS-1
off
DS-2
on
DS-3
off
DS-4
on
DS-5
off
DS-6
off
DS-7
on
DS-8
DS-1
on
DS-2
off
DS-3
on
DS-4
on
DS-5
on
DS-6
on
DS-7
off
DS-8
Example 1: (factory setting)
1 No panel or remote
switch connected
2 No panel or remote
switch connected
3, 4 GEL 14.4V
5 Frequency: 50Hz
6 Search mode off
7 AC-in Limit 12Amp
8 Store setting: off→ on→ off
Example 2
1 No panel or remote
switch connected
2 No panel or remote
switch connected
3, 4 AGM 14,7V
5 Frequency: 50Hz
6 Search mode off
7 AC-in Limit 4Amp
8 Store setting: off→ on→ off
Example 3
1 Panel or remote
switch connected
2 Panel or remote
switch connected
3, 4 Tubular plate 15V
5 Frequency: 60Hz
6 Search mode on
7 AC-in Limit 12Amp
8 Store setting: off→ on→ off
Store the settings (DS3-DS7) by changing switch ds-8 from offto on, and then back to off’.
The LEDs ‘charger’ and ‘alarm’ will flash to indicate acceptance of the settings.