EasySolar EasySolar 12/1600/70 EasySolar 24/1600/40
Inverter/charger
Transfer switch 16A
INVERTER
Input voltage range 9,5 – 17V 19 33V
Heavy duty output AC 0 16 A
Output AC1, 2, 3
Output voltage: 230 VAC ± 2%
Frequency: 50 Hz ± 0,1% (1)
Cont. output power at 25°C (3) 1600VA / 1300W
Cont. output power at 40°C 1200W
Peak power 3000W
Maximum efficiency 92% 94%
Zero load power 8W 10W
Zero load power in search mode 2W 3W
CHARGER
AC Input
Input voltage range: 187-265 VAC
Input frequency: 45 65 Hz Power factor: 1
Charge voltage 'absorption' 14,4V 28,8V
Charge voltage 'float' 13,8V 27,6V
Storage mode 13,2V 26,4V
Charge current house battery (4) 70A 40A
Charge current starter battery (A) 4
Battery temperature sensor yes
Programmable relay (5) yes
Protection (2) a - g
Solar Charge Controller
Model MPPT 100/50
Maximum output current 50 A
Maximum PV power, 6a,b) 700W 1400W
Maximum PV open circuit voltage 100V 100V
Maximum efficiency 98%
Self-consumption 10 mA
Charge voltage 'absorption', default setting 14,4V 28,8V
Charge voltage 'float', default setting 13,8V 27,6V
Charge algorithm multi-stage adaptive
Temperature compensation -16 mV / °C -32 mV / °C
Protection a - g
COMMON CHARACTERISTICS
Operating temp. range -20 to +50°C (fan assisted cooling)
Humidity (non-condensing): max 95%
ENCLOSURE
Material & Colour aluminium (blue RAL 5012)
Protection category IP 21
Battery-connection Battery cables of 1.5 meter
PV connection Three sets of MC4 (PV-ST01) PV connectors.
230 V AC-connection G-ST18i connector
Weight 15kg
Dimensions (hxwxd) 745 x 214 x 110mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29, EN 62109
Emission / Immunity EN 55014-1, EN 55014-2, EN 61000-3-3
Automotive Directive 2004/104/EC
1) Can be adjusted to 60Hz and to 240V
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230 VAC on inverter output
g. Input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25°C ambient
5) Programmable relay which can be set for general alarm, DC under
voltage or genset start signal function
6a) If more PV power is connected, the controller will limit input power to
700 W resp. 1400 W
6b) PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter minimum PV voltage is Vbat + 1V