Product Manual

26
Charger settings menu
Enable charger Setting Switch the charger on or off.
Weak AC input Setting Enable this setting if poor A.C. input causes
charging problems.
Stop after 10 hr Setting Enable this setting to prevent overcharging
damaged batteries. Disable this setting if your
battery requires a bulk period of more than 10
hours.
Battery type Setting Select the type of battery that is connected.
Storage mode Setting Enable this setting to use a voltage set point of
13.2 V (for a 12 V system); otherwise the
normal float voltage will be used.
Use TPTB curve Setting Use the tubular plate traction battery charging
curve.
Charging chars Setting Select which charging algorithm should be
used.
Absorption voltage Setting Specify the absorption voltage to be used
when charging.
Float voltage Setting Specify the float voltage to be used when
charging.
Charge current Setting The amount of current used to charge the
battery.
Rep abs time Setting Specify the duration of repeated absorption
pulses.
Rep abs interval Setting Specify the interval between repeated
absorptions
Max abs time Setting Specify the maximum period of time the
absorption phase should last.
VVC menu
Device name
Setting The name that will appear in the VPN’s device
list.
PowerAssist Setting If enabled, the inverter will start up if the
current consumption becomes too high, to
prevent tripping the external breaker.
Boost factor Setting Used to calculate the required current during
PowerAssist.
AES Setting Reduces the current drawn when the inverter
load is low, but can take more time to switch to
full load.
Start AES below Setting When power consumption drops below this
point AES will be activated if it is enabled.
Stop AES above Setting AES mode will be deactivated if power
consumption rises above this level.
AES type Setting Selects the waveform type to be used during
AES operation.