Manual

The settings in the advanced menu (with expert mode disabled) include:
a. Battery preset
The ‘Battery preset’ dropdown allows selection from the following options:
i. Built-in preset
Selection of a standard integrated pre-set (same as the general settings menu)
ii. User defined
Reselection of the last ‘user defined’ charge settings
iii. Select preset
Selection from an extended range of integrated battery charging pre-sets, including new user defined charging pre-sets
iv. Create preset
A new charging preset to be created and saved from user defined settings
v. Edit presets
An existing preset to be edited and saved
b. Maximum charge current
The maximum charge current setting allows selection between the standard (full current) or a significantly reduced charge
current limit (varies per model - refer to specifications), same as through the general settings menu.
c. Charge voltage
The charge voltage settings enable the voltage setpoint for each charge stage to be independently configured and some
charge stages (recondition and float) to be disabled or enabled.
The charge voltage setpoint for the following charge stages can be configured:
i. Absorption
ii. Float
iii. Storage
iv. Recondition
d. Voltage compensation
i. Temperature Compensation
The temperature compensation setting enables the charge voltage temperature compensation coefficient to be
configured, or temperature compensation to be totally disabled (such as for Li-ion batteries).
The temperature compensation coefficient is specified in mV/°C and applies to the entire battery/battery bank (not per
battery cell).
Blue Smart IP22 Charger
Page 23 Advanced Configuration