User Manual
7 
The low current mode remains activated until the MODE button is 
pressed again during 3 seconds. 
2.  BULK 
Charges the battery with maximum current until absorption 
voltage is reached. The battery will then be about 80% 
charged and is ready for use. 
3.  ABS - Absorption 
Charges the battery at constant voltage and with 
decreasing current until it is fully charged. 
See table above for absorption voltage at room 
temperature. 
Adaptive battery management: 
The absorption time is short (minimum 30 minutes) if the 
battery was (nearly) fully charged and increases to 8 hours 
in case of a deeply discharged battery. 
4.  RECONDITION 
Optional reconditioning for deeply discharged lead-acid 
batteries. 
Reconditioning is applicable to the charge algorithms 
NORMAL and HIGH and can be selected by pressing the 
MODE button one more time after selection of the required 
algorithm. 
When in RECONDITION mode the battery will be charged 
with low current up to a higher voltage at the end of the 
absorption phase. 
The RECONDITION LED will be on during charging, and 
will blink during the reconditioning period. 
During reconditioning the maximum current is equal to 8% 
of the nominal current until the maximum voltage is 
reached. Reconditioning is terminated after one hour or 
when the maximum voltage is reached, whichever comes 
first. See table. 
Example: 
For a 12/15 charger: the recondition current is 
15 x 0,08 = 1,2A. 
5.  FLOAT 
Keeps the battery at constant voltage and fully charged. 
6.  STORAGE 
Keeps the battery at reduced constant voltage to limit 
gassing and corrosion of the positive plates. 
Slow self-discharge is prevented by an automatic weekly 
refresh of the battery with a short absorption charge. 