i)  Storage stage 
An additional stage to extend battery life whilst the battery is unused and on continuous charge. 
j)  Recondition stage 
An optional stage that can partially recover/reverse lead acid battery degradation due to 
sulfation; typically caused by inadequate charging or if the battery is left in a deeply discharged 
state. 
k)  Low current mode 
An optional mode that limits the maximum charge current to a significantly reduced level; 
recommended when charging lower capacity batteries with a high current charger. 
l)  Recovery function 
The Blue Smart Charger range will attempt to recharge a severely discharged battery (even 
down to 0V) with low current and then resume normal charging once the battery voltage has 
risen sufficiently - many other chargers will not recognise a battery in this state. 
m)  Power supply mode 
A specific mode to use the charger as a DC power supply; to power equipment at a constant 