User Manual
23 
EN  NL  FR  DE  ES  IT  PT 
To access expert mode and expand the advanced settings menu, enter the advanced setting 
menu and enable the ‘Expert mode’ switch. 
The additional settings in the advanced menu with expert mode enabled include:  
a)  Charge Voltage 
i.  BatterySafe 
The BatterySafe setting allows the BatterySafe voltage control to be enabled or disabled. When 
BatterySafe is enabled, the rate of battery voltage increase during bulk stage is automatically 
restricted to a safe level. 
In cases where the battery voltage would otherwise increase at a faster rate, the charge current 
is consequently reduced to prevent excessive gassing. 
b)  Bulk 
i.  Bulk time limit 
The bulk time limit setting restricts the maximum time the charger can spend in bulk stage as a 
protection measure, since the absorption voltage should have been achieved by this time. If the 
bulk time limit is satisfied the charger will move directly to float stage.  
ii.  Re-bulk current 
The re-bulk current setting is the charge current limit that will trigger a new charge cycle if 
exceeded during float or storage stage, causing the charger to move back into bulk charge 
stage. 
Note that even when the re-bulk setting is disabled, re-bulk will still occur if the charge current is 
maintained at the maximum charge current for 4 seconds. 
c)  Absorption 
i.  Adaptive absorption time 
The adaptive absorption time setting allows selection between adaptive absorption time (if 
enabled) or a fixed absorption time (if disabled). 
ii.  Absorption time 
The adaptive absorption time setting enables the maximum adaptive absorption time or the 
fixed absorption time to be configured (depending if adaptive absorption time is enabled or 
disabled). 
iii.  Repeated absorption 
The repeated absorption time setting enables the elapsed time between each automatic refresh 
charge cycle (1h in absorption stage) to be configured. 
d)  Recondition 
i.  Recondition stop mode 
The recondition stop mode setting allows selection between the recondition stage being ended 
upon the battery voltage reaching the recondition stage voltage setpoint or a fixed time period. 
ii.  Recondition duration 
The recondition time setting enables the maximum recondition time or the fixed recondition time 
to be configured (depending on the recondition stop mode selected). 