3.3 Commencing a new charge cycle 
A new charge cycle will commence when: 
i.  Bulk stage is complete and the current output increases to the maximum charge current 
for four seconds (due to a simultaneously connected load) 
ii.  If re-bulk current is configured; the current output exceeds the re-bulk current in float or 
storage stage for four seconds (due to a simultaneously connected load) 
iii.  The MODE button is pressed or a new charge mode is selected 
iv.  VictronConnect is used to select a new charge mode or change the function from ‘Power 
Supply’ to ‘Charger’ mode 
v.  The AC supply has been disconnected and reconnected 
3.4 Estimating charge time 
A lead acid battery is at approximately 80% state of charge (SOC) when the bulk charge stage 
is completed. 
The bulk stage duration T
bulk
 can be calculated as T
bulk
 = Ah / I, where I is the charge current 
(excluding any loads) and Ah is the depleted battery capacity below 80% SOC. 
An absorption period T
abs
 of up to 8 hours may be required to fully recharge a deeply 
discharged battery. 
For example, the charge time of a fully discharged 100Ah battery when charged with a 10A 
charger to approximately 80% SOC is T
bulk
 = 100/10 = 10 hours. 
Including an absorption duration of T
abs
 = 8 hours
,
 the total estimated charge time would be T
total
= T
bulk
 + T
abs
 = 10 + 8 = 18 hours. 
A Li-ion battery is more than 95% charged at the end of the bulk stage and reaches 100% 
charge after approximately 30 minutes of absorption charge. 