3. Charge algorithms 
3.1 Smart charge algorithm with optional reconditioning for 
lead-acid batteries 
Charge voltages at room temperature: 
MODE 
ABS 
V 
FLOAT 
V 
STORAGE 
V 
RECONDITION 
Max V@% of Inom 
NORMAL 
14,4 
13,8 
13,2 
16,2@8%, max 1h 
HIGH 
14,7 
13,8 
13,2 
16,5@8%, max 1h 
LI-ION 
14,2 
13,5 
13,5 
n.a. 
For 24V chargers: multiply all voltage values by 2. 
NORMAL (14,4V): recommended for flooded flat plate lead 
antimony batteries (starter batteries), flat plate gel and AGM 
batteries. 
HIGH (14,7V): recommended for flooded lead calcium batteries, 
Optima spiral cell batteries and Odyssey batteries. 
The MODE button 
After connecting the charger to the AC supply, press the MODE-
button to select another charging algorithm if required (the 
charger remembers the mode when disconnected from the mains 
and/or the battery). 
If reconditioning is selected, the RECONDITION LED will be on, 
and will flash when reconditioning is active. 
The charger switches to NIGHT by pressing the MODE button 
during 3 seconds. The NIGHT LED will turn on. The NIGHT mode 
automatically ends after 8 hours, and can be ended earlier by 
again pressing the MODE button during 3 seconds.  
The charger switches to LOW by pressing the MODE button 
during 6 seconds. The NIGHT LED will blink twice per second. 
The LOW mode remains activated until the MODE button is 
pressed again during 6 seconds. 
When NIGHT or LOW are on, the output current is reduced to 
max. 50% of the nominal output and the charger will be totally 
noiseless. 