With cell balancing, but without BMS: 12,8V LFP batteries for light duty applications
In applications were excessive discharge (to less than 11V), overcharge (to more than 15V) or excessive charge/discharge current will
never occur, 12,8V batteries with cell balancing only may be used.
Please note that these batteries are not
suitable for series or parallel connection.
Notes:
1. A Battery Protect module (see www.victronenergy.com) may be used to prevent excessive discharge.
2. The current draw of inverters and inverter/chargers is often still significant (0,1A or more) after low voltage shutdown. The
remaining stand-by current will therefore damage the battery if the inverters or inverter/chargers are left connected to the
battery after low voltage shutdown during a long period of time.
With cell balancing and interface to connect to a Victron BMS: 12,8V LFP batteries for heavy duty applications and
parallel/series connection
The batteries with suffix BMS are fitted with integrated Balancing, Temperature and Voltage control (BTV). Up to ten batteries can be
paralleled and up to four batteries can be series connected (BTV’s are simply daisy-chained) so that a 48V battery bank of up to 2000Ah
can be assembled. The daisy-chained BTV’s must be connected to a battery management system (BMS).
Battery Management System (BMS)
The BMS connects to the BTV’s and its essential functions are:
1. Disconnect or shut down the load whenever the voltage of a battery cell falls to less than 2,5V.
2. Stop the charging process whenever the voltage of a battery cell increases to more than 4,2V.
3. Shut down the system whenever the temperature of a cell exceeds 50 °C.
More features may be included: see the individual BMS datasheets.
Battery specification
Cell balancing only Cell balancing and BMS interface
VOLTAGE AND CAPACITY
LFP-CB
12,8/60
LFP-CB
12,8/90
LFP-CB
12,8/160
LFP-CB
12,8/200
LFP-BMS
12,8/60
LFP-BMS
12,8/90
LFP-BMS
12,8/160
LFP-BMS
12,8/200
Nominal voltage 12,8V 12,8V 12,8V 12,8V 12,8V 12,8V 12,8V 12,8V
Nominal capacity @ 25°C*
60Ah 90Ah 160Ah 200Ah 60Ah 90Ah 160Ah 200Ah
Nominal capacity @ 0°C*
48Ah 72Ah 130Ah 160Ah 48Ah 72Ah 130Ah 160Ah
Nominal capacity @ -20°C*
30Ah 45Ah 80Ah 100Ah 30Ah 45Ah 80Ah 100Ah
Nominal energy @ 25°C*
768Wh 1152Wh 2048Wh 2560Wh 768Wh 1152Wh 2048Wh 2560Wh
*Discharge current ≤1C
CYCLE LIFE
80% DoD 2000 cycles
70% DoD 3000 cycles
50% DoD 5000 cycles
DISCHARGE
Maximum continuous
discharge current
180A 270A 400A 500A 180A 270A 400A 500A
Recommended continuous
discharge current
60A 90A 160A 200A 60A 90A 160A 200A
Maximum 10 s pulse current 600A 900A 1200A 1500A 600A 900A 1200A 1500A
End of discharge voltage 11V 11V 11V 11V 11V 11V 11V 11V
OPERATING CONDITIONS
Operating temperature -20 - 50°C
Storage temperature -45 - 70°C
Humidity (non condensing) Max. 95%
Protection class IP 54
CHARGE
Charge voltage 14,4V 14,4V 14,4V 14,4V 14,4V 14,4V 14,4V 14,4V
Float voltage 13,6V 13,6V 13,6V 13,6V 13,6V 13,6V 13,6V 13,6V
Maximum charge current 60A 90A 160A 200A 180A 270A 400A 500A
Recommended charge current
20A 25A 40A 50A 30A 45A 80A 100A
OTHER
Max storage time @ 25 °C* 1 year
Dimensions (hxwxd) mm
235x293x139 249x293x168 320x338x233 295x425x274 235x293x139 249x293x168 320x338x233 295x425x274
Weight 12kg 16kg 28kg 37kg 12kg 16kg 28kg 37kg
*When fully charged
12,8 VOLT LITHIUM IRON PHOSPHATE BATTERIES