Technical information

43
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40
E-mail: sales@victronenergy.com | www.victronenergy.com
Skylla-TG
24/30
90-265 VAC
24/50
90-265 VAC
24/100-G
90-265 VAC
Input voltage (V AC) 230 230 230
Input voltage range (V AC) 90-265 90-265 90-265
Input voltage range (V DC) 90-400 90-400 90-400
Frequency (Hz) 45-65 Hz or DC
Power factor 1
Charge voltage 'absorption' (V DC) 28,5 28,5 28,5
Charge voltage 'float' (V DC) 26,5 26,5 26,5
Charge current house batt. (A) (2) 30 50 100
Charge current starter batt. (A) 4 4 4
Charge characteristic IUoUo (three step)
Battery capacity (Ah) 150-300 250-500 500-1000
Temperature sensor
Can be used as power supply
Remote alarm Potential free contacts 60V / 1A (1x NO and 1x NC)
Forced cooling
Protection (1) a,b,c,d
Operating temp. range -20 to 60°C (0 - 140°F)
Humidity (non condensing) max 95%
ENCLOSURE
Material & Colour aluminium (blue RAL 5012)
Battery-connection M8 studs
230 V AC-connection screw-clamp 2,5 mm² (AWG 6)
Protection category IP 21
Weight kg (lbs) 5,5 (12.1) 5,5 (12.1) 10 (22)
Dimensions hxwxd in mm
(hxwxd in inches)
365x250x147
(14.4x9.9x5.8)
365x250x147
(14.4x9.9x5.8)
365x250x257
(14.4x9.9x10.1)
STANDARDS
Vibration 0,7g (IEC 60945)
Safety EN 60335-1, EN 60335-2-29, IEC 60945
Emission EN 55014-1, EN 61000-3-2, IEC 60945
Immunity EN 55014-2, EN 61000-3-3, IEC 60945
Germanischer Lloyd Certificate 54 758 – 08HH
1) Protection key:
a) Output short circuit
b) Battery reverse polarity detection
c) Battery voltage too high
d) Temperature too high
2) Up to 40°C (100°F) ambient
BMV-600
S
Battery Monitor
The BMV – 600 Battery Monitor
features an advanced
microprocessor control system
combined with high resolution
measuring systems for battery
voltage and charge/discharge
current. Besides this, the software
includes complex calculation
algorithms, like Peukert’s formula,
to exactly determine the state of
charge of the battery. The BMV –
600 selectively displays battery
voltage, current, consumed Ah or
time to go.
Skylla Control
The Skylla Control allows you to
alter the charge current and see
the system status. Altering the
charge current is useful if the
shore power fuse is limited: the
AC current drawn by the battery
charger can be controlled by
limiting the maximum output
current, thereby preventing the
shore power fuse from blowing.
Charger Switch
A remote on-off switch
Battery Alarm
An excessively high or low battery
voltage is indicated by an audible and
visual alarm.
SKYLLA TG CHARGER 24V 90265V GL APPROVED