Technical information
25
PHOENIX INVERTERS 180VA 1200VA 120V AND 230V
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40
E-mail: sales@victronenergy.com | www.victronenergy.com
Phoenix Inverter
12 Volt
24 Volt
48 Volt
12/180
24/180
12/350
24/350
48/350
48/750
12/800
24/800
48/800
12/1200
24/1200
48/1200
Cont. AC power at 25 °C (VA)
(3)
180 350 750 800 1200
Cont. power at 25 °C / 40 °C (W) 175 / 150 300 / 250 700 / 650 700 / 650 1000 / 900
Peak power (W) 350 700 1400 1600 2400
Output AC voltage / frequency
(4)
110VAC or 230VAC +/- 3% 50Hz or 60Hz +/- 0,1%
Input voltage range (V DC) 10,5 - 15,5 / 21,0 - 31,0 / 42,0 - 62,0 9,2 - 17,3 / 18,4 - 34,0 / 36,8 - 68,0
Low battery alarm (V DC) 11,0 / 22 / 44 10,9 / 21,8 / 43,6
Low battery shut down (V DC) 10,5 / 21 / 42 9,2 / 18,4 / 36,8
Low battery auto recovery (V DC) 12,5 / 25 / 50 12,5 / 25 / 50
Max. efficiency (%) 87 / 88 89 / 89/ 90 94 91 / 93 / 94 92 / 94 / 94
Zero-load power (W) 2,6 / 3,8 3,1 / 5,0 / 6,0 13 6 / 5 / 4 6 / 5 / 6
Zero-load power in search mode
n. a. n. a. 5 2 2
Protection
(2)
a - e
Operating temperature range -40 to +50°C (fan assisted cooling)
Humidity (non condensing) max 95%
ENCLOSURE
Material & Colour aluminium (blue Ral 5012)
Battery-connection 1) 1) Screw terminals 1) 1)
Standard AC outlets
230V: IEC-320 (IEC-320 plug included), CEE 7/4 (Schuko)
120V: Nema 5-15R
Other outlets (at request)
BS 1363 (United Kingdom)
AN/NZS 3112 (Australia, New Zealand)
Protection category IP 20
Weight (kg / lbs) 2,7 / 5,4 3,5 / 7,7 2,7 / 5,4 6,5 / 14.3 8,5 / 18.7
Dimensions (hxwxd in mm)
(hxwxd in inches)
72x132x200
2.8x5.2x7.9
72x155x237
2.8x6.1x9.3
72x180x295
2.8x7.1x11.6
108x165x305
4.2x6.4x11.9
108x165x305
4.2x6.4x11.9
ACCESSORIES
Remote control panel n. a. n. a. Optional n. a. n. a.
Remote on-off switch Two pole connector RJ12 plug Two pole connector
Automatic transfer switch Filax
STANDARDS
Safety EN 60335-1
Emission Immunity EN55014-1 / EN 55014-2/ EN 61000-6-2 / EN 61000-6-3
1) Battery cables of 1.5 meter (12/180 with
cigarette plug)
2) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
3) Non linear load, crest factor 3:1
4) Frequency can be set by DIP switch (48V/750VA model only)
Battery Alarm
An excessively high or low battery voltage is indicated
by an audible and visual alarm, and a relay for remote
signalling.
BMV Battery Monitor
The BMV Battery Monitor features an advanced
microprocessor control system combined with high
resolution measuring systems for battery voltage and
charge/discharge current. Besides this, the software
includes complex calculation algorithms to exactly
determine the state of charge of the battery. The BMV
selectively displays battery voltage, current, consumed
Ah or time to go. The monitor also stores a host of data
regarding performance and use of the battery.