User manual

Setup Controller
[Press Enter]
GMDSS Monitor
24.7V 0.0A 100%
8.3 Settings of the GMDSS Monitor
In order to prevent accidental change of the settings of the GMDSS monitor, access to setup values during operation should in
general be prevented. If the setup values are not visible, make sure the panel is in “User and Install” mode. For details about
the access level, refer to paragraph 7.4. If the OEM installer has locked the panel at the user level, it is not possible to change
the access level!
8.4 Where to find the “Setup Alarms” menu
Step 1.) Press “Enter” to enter the GMDSS Monitor menu.
Step 2.) Press “” to scroll through the menu until you see “Setup Alarms”.
Note: If you can’t find the Setup Alarms” menu, make sure that your panel is in “User and
Install” mode.
Step 3.) Press “Enter” to enter the “Setup Controller” menu.
8.5 The “Setup Alarms” menu
Several alarms can be adjusted to suit the needs of a particular setup. The High Voltage and Low Voltage alarms are however always
enabled and can not be turned off. The “charger failure” alarm is also always enabled and indicates the failure of the GMDSS charger to
charge the battery.
Setup Alarms Default Range Step size
Low Voltage
The DC Voltage has to be below this threshold to trigger the
Low Voltage alarm.
20 8 - 33 0.1
Low Voltage Clr
The threshold that has to be reached again to cancel a Low
Voltage alarm.
22 8 - 33 0.1
High Voltage
The DC Voltage has to be above this threshold to trigger the
High Voltage alarm.
32 8 - 33 0.1
High Voltage Clr
The threshold that has to be reached again to cancel a High
Voltage alarm.
31 8 - 33 0.1
Low SOC
The low State of Charge threshold that will activate the
alarm.
60% 0 - 100 1
Low SOC Clr
The State of Charge threshold that has to be reached to
cancel a State of Charge alarm.
60% 0 - 100 1
Low SOC Alarm Enables and disables the low SOC alarm. off on - off
Low Current
The current has to be below threshold to trigger the Low
Current alarm.
-100 -100 - 100 0.5
Low Current Clr.
The threshold that has to be reached again to cancel a Low
Current alarm.
-98 -100 - 100 0.5
Low Current Alarm Enables and disables the low current alarm. off on-off
High Current
The current has to be above this threshold to trigger the
High Current alarm.
35 -100 - 100 0.5
High Current Clr
The threshold that has to be reached again to cancel the
High Current alarm.
32 -100 - 100 0.5
High Current Enables and disables the high Current Alarm. off on - off
Consumed Ah
0.0