7.5 Alarms
Whenever an alarm is active on the GMDSS charger, the VE.Net GMDSS panel will draw attention from the user while showing
relevant information on the screen. The relay will also indicate the presences of an alarm. The relay is closed during normal
operation. It is open for as long as one or more alarm conditions are present. The behavior of the panel with respect to alarms
is described in more detail below
If a new alarm conditions is present
• The audible alarm becomes active
• The relay is open
• the screen blinks
• Information about the alarm is shown on the screen, mentioning:
o Mentioning that an alarm is active and on which device
o Continuously alternated with a description of the alarm and relevant information.
Confirming the alarm
Press enter to confirm that the alarm has been noticed.
• The audible alarm silences
• The relay remains open
• the screen continues to blink as long as the alarm condition is present
• A reminder of the alarm will periodically be shown
The alarm condition is removed
• The relay is closed
• If the alarm condition was confirmed on the panel, it will resume normal operation.
• If the alarm condition was not yet confirmed the audible alarm will silence and information about the alarm will remain
visible on the screen to indicate that an alarm has occurred. By pressing enter normal operation is resumed.
If multiple alarms are present at the same time, all of them must be confirmed once and all alarms will be repeated. The relay
will close after all alarm conditions are removed.
Description of the alarm
Reading of the related parameter