User manual

Setup Controller
[Press Enter]
GMDSS Monitor
24.7V 0.0A 100%
8.6 Where to find the “Setup Controller” menu
Step 1.) Press “Enter” to enter the GMDSS Monitor menu.
Step 2.) Press “” to scroll through the menu until you see “Setup Controller”.
Step 3.) Press “Enter” to enter the Setup Controller menu.
8.7 The “Setup Controller” menu
Setup Controller Default Range Step size
Battery Capacity The battery capacity in amp hours (Ah) at a 20h discharge rate. 200Ah 20-65535 5
Volt charged par
The battery controller considers the battery as fully charged if the
voltage is above this level.
26.4V 8-33 0.1
Curr charged par
If the charge current is below this percentage of the battery
capacity, the battery can be considered as fully charged.
4% 1-10 1
Charged time par
The minimum time that the above two parameters must be met to
consider the battery as fully charged.
4 min 1-4 1
Charge eff. Factor
When a battery is charged, energy is lost. The charge efficiency
factor compensates for the lost energy, where 1 is no loss of
energy and 0.5 is a 50% loss of energy.
0.9 0.5-1 0.05
Resynchronize? Resets the state of charge manually to 100%.
9 Technical specifications
VE.Net
Maximum cable length 25 meter
VE.Net GMDSS Panel VPN
Power supply voltage range 9 – 35 V DC
Operating temp. range -20 – +50°C (0 - 120°F)
Potential free contact 3A / 30 V DC / 250 V AC / (Normally closed)
ENCLOSURE
Measurements front panel (w x h) 12 x 6,5 cm (Standard PROS3 Panel)
Measurements body (w x h) 10 x 4,5 cm
Weight 0,1 Kg
Contact:
Victron Energy
De Paal 35
1351JG Almere
The Netherlands
T: +31 (0)36 535 9700
F: +31 (0)36 531 1666
info@victronenergy.com
www.victronenergy.com
revision 1.00
Consumed Ah