Instruction Manual
Catamaran setup Quattro 5kVA 230VAC 24VDC 600Ah Li Lynx Smart BMS & distributors
Cerbo GX touch generator MPPT Extra Alternators & WS500.pdf
What is this drawing about ?
This drawing has been setup for catamarans and can be used for sail or motor cats using !
24V DC with 230V/50Hz AC but can easily be used for 120V/60Hz as well.!
This Victron system works as follows:
This system has been build around the 5kVA Quattro with 3 x 200Ah 24 Volt Li battery capacity. !
Protection of the Li batteries from a charge and discharge point of view is in good hands with use
of the Lynx Smart BMS.!
To make sure you will not run out of power that easy, there are multiple charge possibilities
available for this setup:!
1. AC Shore Power that will enable the 5kVA Quattro to charge with 120 Amps towards the
Li batteries.!
2. AC Generator Power that will enable the 5kVA Quattro to charge with 120 Amps towards the
Li batteries.!
3. DC Solar Power that will enable the 2 x Smart Solar MPPT 100|50 to charge towards the Li
batteries. The total Charge capacity depends on the installed Solar array for each MPPT. !
4. DC Engine charging power with an extra 24V/110A Alternator mounted on each engine that
can either charge as standalone with 110 Amps or with both engines running with 220 Amps. !
Charge combinations of the above mentioned devices also are possible.!
DC Loads or users like lights, pumps, and so on, can be connected behind one of the two Smart
Battery Protect 220 where the loads are split between main fuse 1 till 5 and 6 till 10.!
AC Power will be available from the 5kVA Quattro Inverter/Charger the moment it has been
switched on. This means that without any AC power on the input, the Quattro will give you 5kVA
of inverter power on AC OUT-1. The moment AC Power is available on input AC IN-1 or AC IN-2,
of the Quattro, AC Power will be used to charge the batteries and also is available for loads
connected to AC OUT-1 and AC OUT-2. With use of the Cerbo one can adjust the available AC
Shore power to the maximum AC current the Quattro will use and this is where the Power Assist
function comes into play. Power Assist allows to supplement AC inverter power to for instance a
limited Shore power connection when needed.!
All information about the system and its connected Victron devices is clearly visible on the GX
Touch 50 Screen that is connected to the Cerbo GX. All AC Input power and AC Loads are clearly
visible. Here you can monitor what the SOC or state of charge is from your Li batteries and you
also can exactly see what discharge current runs away and what charge current comes into the
batteries. This will give you a rest asure feeling that you are in control of your “on board” AC and
DC power availability. More info about the system and its individual Victron parts used in this
installation are explained in more details down below.!
This is how the system has been setup:
Around the Victron Lithium Batteries 25.6V Smart and Lynx Distributor-1 (Dip switch Pos-A)
A Lynx Distributor is an easy to use and connect DC distribution system. It can hold 4 Mega fuses
and three of them are in use here. It is important to always start with connecting the negative
cable first before connecting the positive for each distribution position. Read the manual for
additional information. !
1. The first fuse position at the bottom of Distributor-1 holds a 300A fuse together with its lower
positioned negative for Li Battery-1.!
2. The second fuse position of Distributor-1 holds a 300A fuse together with its lower positioned
negative for Li Battery-2.!
3. The third fuse position of Distributor-1 holds a 300A fuse together with its lower positioned
negative for Li Battery-3.!
4. The forth fuse position of Distributor-1 holds a spare fuse together with its lower positioned
negative for a spare Li battery.!
Lynx Smart BMS:
The Lynx Smart BMS is connected between Lynx Distributor-1 and Lynx Distributor-2!
The BMS is the controlling safety heart of the system as this device protects the LiFePO4
batteries against over Voltage, under Voltage and high temperature. The Victron Lithium Batteries
Page-1