Specifications
CUTMASTER A120 
Manual 0-4989  5-3   SERVICE
5.04  Fault Indicator
At initial power up, two lights will temporarily illu-
minate for 2-3 seconds to show the version of software 
used. 
To determine the first digit, count the function indicators 
left to right, 1 through 5. To determine the second digit 
count the pressure indicators, reading from bottom to 
top, 0 through 7. In the example below the Temp indica-
tor and 76 psi indicators are ON indicating the version 
would be 2.3.
A
+
PSI BAR
MAXMAX
MINMIN
!
1
2
3
4
Art# A-07988
MIN
MAX
0
1
2
3
4
5
6
7
5
When the 
!
 "Fault" indicator is ON or blinking it 
will be accompanied by one of the pressure indicator 
lights depending on what the Fault is. The following 
table explains each of those Faults.
Pressure 
Indicator
Fault
Max Over Pressure
90 Internal Error
85 Shorted Torch
80 Consumables Missing
75 Start Error
70 Parts in Place 
65 Input Power
Min Under Pressure
NOTE
Fault explanations are covered in the following 
tables.