User guide
UG:106 vicorpower.com Applications Engineering: 800 927.9474 Page 7
ConverterPAC Functional Description (Cont.)
FlexPAC
The FlexPAC output assembly consists of from 2 to 4 discrete outputs that convert the
high voltage bus to the desired output voltage. Each FlexPAC output can be manually
trimmed from 2 V to 25 V and supports up to 5 amps with a maximum output power
of 50 W per output. All outputs maintain less than 50 mV noise over the entire output
range. All outputs support local sense only. For electrical trim options and speciļ¬c
output sequencing contact the factory.
List of ConverterPACs used in the Autoranging MegaPAC and their features
ConverterPAC OVP OCP OTL RS/AS* LS/AS* PG TrimPot
ModuPAC Std Std Std AS* AS* Opt Opt
JuniorPAC N/A Std N/A AS* AS* Opt Opt
DualPAC N/A Std N/A AS* AS* N/A Opt
RAMPAC N/A Std N/A AS* AS* Opt Opt
BatPAC N/A Std N/A N/A N/A N/A Std
FlexPAC Std Std Std LS LS N/A Std
* See page 11 and 14 for more information on Autosense.
OVP Overvoltage Protection (latching) OCP Overcurrent Protection (auto-recovery)
OTL Overtemperature Limiting (latching) RS Remote Sense
PG Power Good (DC OK TTL Signal) LS Local Sense
AS Autosense
Note: All ConverterPACs mentioned above can be paralleled EXCEPT the DualPAC, JuniorPAC
and RamPAC.