User guide
UG:105 vicorpower.com Applications Engineering: 800 927.9474 Page 2
Manufactured at Vicor, the entire family of MegaPAC power supplies is completely
user-configurable. If output requirements change, i.e., more power or a dierent
output voltage is needed, upgrading is easy: simply unlock a single screw and replace
the slide-in ConverterPAC assembly with one that is of the same length and has the
desired voltage power rating. For additional flexibility, ConverterPACs can be connected
in parallel to increase output power (booster ConverterPACs), or in series for higher
voltages (total output voltage should not exceed 400 V). The driver is to the le of
the boosters when looking at the output end of the supply. A user-friendly interface
provides control and output sequencing capability (see page 30 for more information
about this capability), in addition to useful status indicators. Please consult our
Applications Engineering Department if you have other special requirements.
Standard Features
n Power Factor Correction; 0.99 at 115 Vac, 0.95 at 230 Vac - both at full load (47-63Hz)
n Universal Input: 85-264 Vac, 47-500 Hz, or 100-380 Vdc
nPower Outputs:
Standard Chassis: 1,600W at 230 Vac High Power Chassis: 2,400W at 230 Vac
1,200W at 115 Vac 1,200W at 115 Vac
nOutputs:
Standard Chassis: Up to 32 outputs High Power Chassis: Up to 32 outputs
n Fan Cooled
n Full power to 40°C; half power to 60°C
n So start for limiting inrush current
n Conducted EMI meets FCC class A and EN 55022 class A
Some configurations meet Class B. Consult Factory
n Harmonic Distortion to EN61000-3-2
n RoHS compliant available
n Output Sequencing and General Shutdown
(Refer pg. 25. Consult Applications Engineering for automatic sequencing circuitry.)
n Overcurrent protection on all outputs
n Overvoltage protection and Overtemperature limiting on all ConverterPAC outputs
(not applicable with VI-J00)
n Size: 3.4”H x 6.0”W x 12.4”L (313,9mm x 152,4mm x 309,mm)
n Safety Agency Approvals: cURus, cTUVus, CE Mark
Optional Features
n DC OK status signal
n Current Share Boards - see pages 26 - 28
n Output voltage adjustment range with built-in potentiometer
n Low Leakage Version available upon request - see page 29
n -40C operation
n Conformal Coating (contact factory)