User guide

UG:115 vicorpower.com Applications Engineering: 800 927.9474 Page 9
Interface Connections
n J3-1 to 3 are Enable/Disable for cards 1-3, respectively.
n J3-4 is Signal Ground, J3-5 is +5V, J3-6 is AC Power OK, and J3-7 is
General Shutdown.
n Use mating receptacle AMP P/N 205204-4 with terminals AMP P/N 66506-9.
n Attach terminals to 18-24 AWG stranded wire.
J3-9
SPARE
J3 INTERFACE PIN OUT
J3-1
J3-2
J3-3
J3-4
J3-5
J3-6
J3-7
J3-8
E/D-1
E/D-2
E/D-3
SIGNAL GROUND
VCC +5V 300mA
ACOK AC POWER OK
GSD GENERAL SHUTDOWN
SPARE
J3 INTERFACE CONNECTION
MATING HDWR:
HOUSING: AMP P/N 205204-4
SCREW LOCK: AMP P/N 205980-4
TERMINALS: AMP P/N 66506-9
CRIMP TOOL: AMP 58448-3