User guide

UG:115 vicorpower.com Applications Engineering: 800 927.9474 Page 22
Environmental (Cont.)
Shock and Vibration
(MI Chassis) Altitude
Mil-STD 810
Derate 2.6% total output power for each 1,000 ft to a maximum
operating altitude of 15,000 ft. Non-operating storage maximum
altitude is 40 K. 75% maximum load
Humidity 0 to 95% non condensing
Product Weight 5.5 lbs. (2,5 kg)
Dimensions 1.72" H (43,6 mm) x 6.0" W (152,4 mm) x 12.2" L (309,9 mm)
Warranty
[c]
2 years limited warranty.
See vicorpower.com for complete warranty statement.
[b]
45°C is the maximum operating temperature. If one is using a Maxi/Mini module less than 24 V output and
more
than 500 Watts, the maximum operating temperature is 40°C.
[c]
Opening, repairing or modifying the unit will void the warranty. If you have any problem with the power supply,
please contact Customer Service at 1-800-735-6200. If the unit needs to be returned for inspection/analysis, an
RMA number will be issued. All units must have a RMA number prior to return.
Ouput
VI-200/VI-J00 Modules
Parameter MIN TYP MAX UNITS Notes
Setpoint Accuracy
[d]
Load/line Regulation
Load/line Regulation
0.5 1
± 0.2
± 0.5
%
%
%
of Vnom
10% to full load
No load to 10% load
Temperature Regulation 0.01 0.02 %/°C Over rated temp.
Long Term Drift
Output Ripple & Noise:
10 Vout
>10 Vout
100
1.0
mV
% Vout
20 MHz bandwidth
20 MHz bandwidth
Voltage Trim Range
VI-200/VI-J00 series Slots 50-110 % Vout ± 10% on 10 – 15 Vout
Total Remote Sense
Compensation
0.5 Volts
Autosense.
See Pages 8 & 14
OVP Set Point
[e]
115 125 135 % Vout Recycle Power
Current Limit 105 115 125 % of I max Auto Recovery
Short Circuit Current 20 (105
[f]
) 130 %
Overtemperature Limiting Not available on VI-J00
[d]
For special, adjustable voltages and 48 Vdc outputs, maximum setpoint accuracy is 2% of Vnom.
Note: See individual module data sheets for specific module specifications.
[e]
131% Nominal for Booster Modules. No OVP for VI-J00
[f]
VI-J00 modules only