User guide
UG:115 vicorpower.com Applications Engineering: 800 927.9474 Page 2
Standard Features
n Power Factor Correction: 0.99 at 115 Vac; 0.95 at 230 Vac
n Universal Input: 85 – 264 Vac, 47 – 500 Hz, or 100 – 380 Vdc
n Power Output: 1,500 W at 230 Vac; 800 W at 115 Vac
n Up to 6 isolated outputs (3 slots)
n Fan cooled
n Full power to 45°C; half power at 65°C
nConducted EMI:
VI-200/VI-J00 series: Maxi, Mini, Micro series:
FCC Class B FCC Class A
EN55022 Class B EN55022 Class A
(certain configurations meet EN55022 Class B)
n Harmonic Distortion complies with EN61000-3-2
n AC Power OK status signal
n Autosense (for more information, see Page 8 and Page 14)
n Output overcurrent protection on all outputs
n Output overvoltage protection (not applicable when using VI-J00)
n Output overtemperature limiting (not applicable when using VI-J00)
n Ride-through (hold-up) time: >20 ms at 1,200 W load (nominal line)
n Size: 1.72" H (43,6 mm) x 6" W (152,4 mm) x 12.2" L (309,9 mm)
n Safety Agency Approvals: CE Mark, cTÜVus, UL
(Note: Certain MI chassis may not carry all safety certs)
Optional Features
n Extended temperature range output converters
n Current share board - see Page 24
n RAM modules for low noise applications - see Page 27
n Connector kit available (#19-130047)
n Low leakage available - see Page 27
n Oce environment fan - see Page 27
n MI chassis specific options
- Mil-STD 810 for Shock and Vibration
- Mil-STD 704 and 1399 for overvoltage and transients
- -40°C Operation
- Conformal coating - contact factory
Mechanical Considerations
The PFC Mini can be mounted on either of two surfaces using standard 8-32 (4 mm) size
screws. Maximum allowable torque is 4.4 in. lbs., and the maximum penetration is