Specifications
Specifications (continued)
Operating Temperature** -20°C to 40°C full power; -20°C to 60°C half power
Humidity 0 to 95% non-condensing
Safety Agency Approvals TUV CUE
Standards: CSA-C22.2 No. 60950-00, UL 60950 3rd Edition, EN 60950:2000
CE Mark to the LVD, 73/23/EEC amended by 93/68/EEC
Product Weights (fully configured) PFC MegaPAC-EL PFC MegaPAC-HPEL
12.8 lbs (5,8 kgs) 13.1 lbs (6kgs)
Warranty 2 years limited warranty.
See vicorpower.com for complete warranty statement.
* See Vicor module specifications. A preload may be necessary for modules trimmed down below 90% of
normal output voltage.
** The maximum operating temperature is 40°C. If using a VI-200 with output voltage less than 12V and
more than 150 Watts, the operating temperature decreases to 35°C. This also applies when using a
FinQPAC with output voltage less than 24 V and more than 500 Watts.
********
Output Studs
New, more robust output studs (with a 3 to 1 safety margin @ 45 in. lbs.) were installed in ConverterPACs,
the slide-in assemblies used in the MegaPAC Family. These new outputs studs are 1/8" longer to allow for multiple
lugs. They are fully compatible with the original flanged nut ConverterPACs for use in parallel arrays. Other advan-
tages include:
• Inner nut (that might become loose) replaced by a brass insert
• Stronger connection to the PCB
• Improved conductivity (less voltage drop and heating)
• Both the stud and panel are less likely to break due to over torqueing
Shown below are the original and re-designed studs.
Original Redesigned
Refer to page 12 for dimensional data.
Rev. 6/2004 Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474 Pg. 19
PFC MegaPAC-EL/PFC MegaPAC-High Power Low Noise