Specifications

Specifications (continued)
Operating Temperature** -20°C to 40°C full power; -20°C to 60°C half power
Humidity 0 to 95% non-condensing
Safety Agency Approvals TUV CUE
Standards: CSA-C22.2 No. 60950-00, UL 60950 3rd Edition, EN 60950:2000
CE Mark to the LVD, 73/23/EEC amended by 93/68/EEC
Product Weights (fully configured) PFC MegaPAC-EL PFC MegaPAC-HPEL
12.8 lbs (5,8 kgs) 13.1 lbs (6kgs)
Warranty 2 years limited warranty.
See vicorpower.com for complete warranty statement.
* See Vicor module specifications. A preload may be necessary for modules trimmed down below 90% of
normal output voltage.
** The maximum operating temperature is 40°C. If using a VI-200 with output voltage less than 12V and
more than 150 Watts, the operating temperature decreases to 35°C. This also applies when using a
FinQPAC with output voltage less than 24 V and more than 500 Watts.
********
Output Studs
New, more robust output studs (with a 3 to 1 safety margin @ 45 in. lbs.) were installed in ConverterPACs,
the slide-in assemblies used in the MegaPAC Family. These new outputs studs are 1/8" longer to allow for multiple
lugs. They are fully compatible with the original flanged nut ConverterPACs for use in parallel arrays. Other advan-
tages include:
Inner nut (that might become loose) replaced by a brass insert
Stronger connection to the PCB
Improved conductivity (less voltage drop and heating)
Both the stud and panel are less likely to break due to over torqueing
Shown below are the original and re-designed studs.
Original Redesigned
Refer to page 12 for dimensional data.
Rev. 6/2004 Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474 Pg. 19
PFC MegaPAC-EL/PFC MegaPAC-High Power Low Noise