Specifications

12
1-800-927-9474
20-10
Three Phase MegaPAC Technical Description (cont)
Upon power-up, all outputs are first disabled to limit the inrush current, and to allow the
unregulated 300Vdc to reach correct operating levels for ConverterPAC assemblies. The
internal housekeeping supply comes up within 500 ms after input power is applied, at which
time the AC Power OK signal asserts to a TTL “1,” indicating that the input power is OK. The
low-voltage power outputs come up within 10-20 ms after the AC Power OK asserts to a TTL
“1.” Output ramp-up time from Enable or General Shutdown is 10-20 ms. Output fall time from
Disable is dependent on load, but typically a few hundred microseconds.
Three Phase MegaPAC Interface Connections
Input Power Connections (J1)
Input AC power is applied to a plug-in connector, J1, that accepts soldered terminals with a
maximum wire size of 12 AWG. For operation on high voltage DC input, input power may be
connected to any two input lines. A fault-clearing device, such as a fuse, at the power supply
input is required per safety agency conditions of acceptability. A user-accessible input fuse is
not present within the unit. For an output of 2000W with operation on 208Vac, 3Ø input, a 20A
slow-blow fuse in each input line is acceptable. Input power cables should be shielded to
minimize radiated noise effects.
The Three Phase MegaPAC can also operate from a single phase 230Vac input; however, the
output power must be limited to 1200W.
Signal Ground (J10)
Signal Ground on J10 pins 1, 2, 12, and 15 is an isolated secondary ground reference for all J10
interface signals. This is not the same as Earth Ground on input power connector J1.
Enable/Disable and General Shutdown (GSD) (J10)
The Enable/Disable control lines allow individual ConverterPAC outputs to be sequenced either
on or off via TTL compatible HCMOS control inputs. For DualPACs, both outputs are
sequenced together. In parallel arrays, only the driver ModuPAC needs to be sequenced. The
GSD control line on J10-5 allows simultaneous shutdown of all ConverterPAC outputs. An
internal jumper, JP2, selects polarity, either active-high or active-low. A jumper, JP1, selects a
pull-up or pull-down source for the HCMOS control inputs.
Applications Manual
Figure 13.
Enable/Disable and
General Shutdown
24
10K
10K
74HC86
5
+5V
JP1
+5V
JP2
Enable/Disable
General Shutdown
Signal Ground 1, 2, 12, 15
1 µF
2N2222
J10