Mechanical Considerations
The 3 Phase MegaPAC can be mounted on any of four surfaces using standard 8-32/M4 screws. The chassis comes
with four mounting points on each surface; maximum allowable torque is 20 lb-in. The maximum penetration is
0.15 in. (3,8mm).
When selecting a mounting location and orientation, the unit should be positioned so air flow is not restricted.
Maintain a 2" minimum clearance at both ends of the 3 Phase MegaPAC and route all cables so airflow is not
obstructed. The standard unit draws air in at the fan side/AC input side and exhausts air out the load side. If airflow
ducting is used, use caution, as sharp turns could present back pressure to the 3 Phase MegaPAC. The fan moves
approximately 30 CFM of air.
Avoid excessive bending of output power cables after they are connected to the 3 Phase MegaPAC. For high-cur-
rent outputs, use cable ties to support heavy cables in order to minimize mechanical stress on output studs. Be care-
ful not to short-out to neighboring output studs. The 3 Phase MegaPAC is supplied with serrated, flanged hex-nuts
on all output studs, so Loc-tite® or lock washers are not required. The maximum torque recommended on flanged
nuts is 45 lb-in. Never loosen the inner nut on a ConverterPAC. This nut supports the hardware inside the
ConverterPAC and is factory torqued.
Avoid applications in which the unit is exposed to excessive shock or vibration levels. In such applications, a shock
absorption mounting design is required.
MegaPAC Do’s and Don’ts
Do not leave ConverterPAC Sense lines open. Always terminate them locally or at the load. Use twisted
pair 22-24 AWG wire.
Always fill all output slots of the MegaPAC. If a slot is not filled with a ConverterPAC, it should be
filled with an airblock. Failure to do so can result in overheating and damage to the power supply.
Do not unplug ConverterPACs while input power is applied. They are not designed for hot-plug
applications.
Do not restrict airflow to the unit. The cooling fan draws air into the unit and forces it out at the output
power terminals.
For power expansion use booster ModuPACs. Viewing the unit from the output terminal side, always insert
boosters to the right side of the driver.
For booster arrays, do not remove busbars.
Always ensure that output hex-nuts are properly torqued before applying power to supply.
Run the output (+/–) power cables next to each other to minimize inductance.
Wait 5 minutes after shutting off power before inserting or removing ConverterPACs.
Do not attempt to repair or modify the power supply in any manner other than the exchange of ConverterPACs
as described in this manual.
Insert proper fault protection at power supply input terminals (i.e., a fuse).
Use proper size wires to avoid overheating and excessive voltage drop.
Never loosen the inner nut on a ConverterPAC.
Verify output nuts are tight before powering up.