Installation guide Manual

Door/Window Sensor
Installation Guide
4
© 2014 Viconics. All rights reserved.
Viconics Technologies Inc. | 9245 Langelier Blvd. | St.-Leonard | Quebec | Canada | H1P 3K9 | Tel: (514) 321-5660 | Fax: (514) 321-4150
028-6076-00 www.viconics.com | sales@viconics.com October 2014
INSTALL MAGNET
This procedure shows you how to install the Magnet to the desired location. You
can use one of the following two options to install the Magnet:
2-sided tape
Screws
Install Magnet in the proper orientation using 2-sided tape or screws. The Magnet
must be within 0.75in (1.9cm) of the Sensor. If using 2-sided tape, the Magnet’s
tab can be removed by snapping the screw tab along the scored line (Figure 1).
Option 1
1. Affix 2-sided tape to desired location.
NOTE: ensure tape is flush with surface and securely affixed to surface.
2. Set Magnet on 2-sided tape and press firmly to secure Magnet in place.
Option 2
1. Using screwdriver, secure Magnet to desired location with two screws.
NOTE: Ensure screws are tight and Sensor does not move easily. Do not
torque screws.
DEVICE FUNCTION
Function and LED Indicators
BUTTON LED ACTION LED DESCRIPTION
2 times GG Network Status
GGG
Joined
RRR Not Joined
YYY Re-Join in Process
4 Times GGGG Network Join
YRY
Searching for Network
YGY Device Being Configured
GGG Device Joined
RRR Device Failed to Join
8 Times
GGGGGGGG
Forced Re-Join YYY Re-Join, Searching for Parent
10 Times
GGGGGGGGGG
Network leave and join a
new Network
RRR Leave if Joined
GGGGG Defaults Restored
G = Green
Y = Yellow
R = Red
No Action
Y Wrong Button Press
YGR Device Busy
Power Up RRYYGG
Figure 1