Wiser Air Installation Guide 1-855-559-4737 www.wiserair.com
Before You Start
Read the information in this section in its entirety before you begin the installation of Wiser Air.
TOOLS PROVIDED MATERIALS
Wire stripper
Drill with 3/16in (4.8mm) drill bit
Screwdriver
Level
Voltmeter
Wiser Air front
Wiser Air back plate
Wiser Air trim plate
Screws (x2) and anchors (x2)
Wire extender
Installation guide
Wire labels
2
Preparation
Make sure that your existing thermostat is in off mode.
Switch your air conditioning and/or heating system breaker to the off position.
We recommend that you use a properly isolated voltmeter to conrm power is off.
Wiring must conform to all building codes, regulations, and ordinances as required
by local and national code and regulation authorities.
Ensure all electrical loads (air conditioners, heating elements, etc.) that will be
controlled by Wiser Air are connected to appropriate fuses to prevent overload.
Ensure Wiser Air is suitable for the environment. Check the voltage compatibility
(~24V).
Wiser Air outputs are rated at 1A maximum.
Security is a top priority for Wiser Air. Wi-Fi must be at least WPA2 password
protected.
Location
If this is a new installation, install Wiser Air 5ft (1.52m) above the oor surface in
accordance with applicable building codes.
Install Wiser Air in areas with frequent occupancy and airow.
Avoid installing Wiser Air in locations near heating/cooling devices.
Avoid installing Wiser Air in areas with direct sunlight. The screen may become
unreadable due to direct sunlight or reection from windows, and temperature
regulation may be affected.
Avoid installing Wiser Air behind doors, near corners, near air vents, or in areas
with high dust concentration.
Mounting
1. Keep the front of Wiser Air separate from the back plate before mounting.
2. Align the Wiser Air back plate against a wall using a level and mark the placement
of the mounting holes.
3. Using a 3/16in (4.8mm) drill bit, drill a hole to a depth of 1in (25.4mm) and install
wall anchors at the marked locations. If a stud is present, no anchors are
necessary.