Installation
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
Disconnect all power before working on equipment.
Failure to follow these instructions will result in death or
serious injury.
TIP: Take a photograph of the initial wiring of the HVAC system to use as a reference and to help
prevent wiring mishaps during the installation process.
1. Disconnect the wires from the Y and W terminals on the thermostat.
2. Connect the diode pair to the Y and W terminals (Fig. 8). Ensure that the diode
pair’s Y terminal is connected to the thermostat’s Y terminal and the diode pair’s
W terminal is connected to the thermostat’s W terminal.
3. Connect the wire that was on W to the diode pair; connect the wire that was on
Y to C.
4. Connect the other wire that was disconnected from the thermostat base to the C
terminal on the thermostat.
RC
G
W2
Y2
O/B
S1
C
RH
U
S2
W
Y
Figure 8 : Diode pair connection.
This wire connects
to the W on the Wire
Extender terminal.
DANGER
16
TIP: Use the picture taken in Step 3 of the Installation procedure for Wiser Air to
help you determine whether you have a 4 or 5-wire system.