Wiser Air Installation Guide 1-855-559-4737 www.wiserair.com
Troubleshooting
If you experience difculties with your Wiser Air thermostat setup, proceed as follows:
Disconnect power.
Check that the front plate of Wiser Air is properly connected to the back plate.
Check that the wires connected to the terminals on the back plate are properly
attached.
Contact the Customer Care Center 1-855-559-4737.
Terminal descriptions
RC Cool 24V power supply Required R, RC
G Fan relay G, F
W2 Heating relay (Stage 2)
W2 (if W, W1 or Aux is
selected)
Y2 Compressor relay (Stage 2) Y2
O/B Cool/Heat active reversing valve O/B, O, B
S1 Outside air sensor S1
C Common Required C, X, B
RH Heat 24V power supply
Only if RC is
connected
RH
W Heating relay
W, W1, W2, AUX
Y Compressor relay
Y, Y1
U Universal (W3)
W3, D, H, E, X2
S2 Outside air sensor
S2
Notes
12
Wiser Air
Terminal
Description
Other brand
terminal equivalents