Figure-1 Open cover
Figure-2 Install Switch and Magnet Bases
INSTALLATION SED - WIN/SED - DOR
Installation
1. Remove cover by pulling on side where security screw was mounted
(Figure-1).
2. Remove cover of magnet unit.
3. Read FCC ID and IC label inside removed cover.
4. Cut out mounting template (end of this manual) for install. Do not place it
on hinge side of door unless self tested.
5. Locate template and mark four holes for self-tapping screws.
6. Use self-tapping screws to install both switch and magnet base
(Figure-2).
7. Follow pairing process before installing switch and magnet units.
8. After pairing process is successful, install switch and magnet units.
9. Install security screw on switch.
Self Testing
For best practice, the configuration of the wireless switch and magnet unit
should be configured as shown. Use mounting template at the end of this
document for installation. Other configurations can be used, such as
placing devices on top of door, placed horizontally. Always self-test wireless
switch to ensure it works correctly.
Location
• Never install switch unit on moving part (door or window).
• Install only magnet unit on moving part (door or window).
• Never install in direct sun.
• Ensure minimum distance between any wireless node and any WiFi devices
is at least 3 feet (1m).
Notes
• Electronic controls are static sensitive devices. Discharge yourself properly
before manipulating and installing device.
• A short circuit or wrong wiring may permanently equipment.
• All SED-WIN and SED-DOR series controls are designed for use as
operating controls only and are not safety devices. These instruments have
undergone rigorous tests and verification prior to shipping to ensure proper
and reliable operation in the field. Whenever a control failure could lead
to personal injury and or loss of property, it becomes the responsibility of
the user, installer, electrical system designer to incorporate safety devices
(relays, flow switch, thermal protections), or an alarm system to protect
the entire system against catastrophic failures. Tampering with devices or
unintended application of devices results in void of warranty.
• See data sheet for operating and storage conditions.
• Any occurring condensation can damage wireless switch.
• Respect polarity when replacing batteries. Reversing polarity of