4. Use camera mounting frame to mark its mounting holes, drill holes and mount using
appropriate hardware.
5. Terminate wires to camera board. Feed the excess wire back through cable clamp and tighten
clamp.
6. Mount front plate to camera mounting frame.
7. When the camera mounting frame is secured to the surface, apply an epoxy security sealant
around the perimeter of the base plate where it meets the ceiling/wall. [Vicon recommends
DynaPoxy™ EP1200 (US) or Arbokol 1025 (UK) or equivalent for this purpose.]
3. Connections
All cabling is done to the boards located on the back of the front plate. Refer to Figure below.
8-pin terminal block on board.
Pinouts are as follows (printed on the board):
Pin1 : AUDIO OUT
Pin 2 : GND
Pin.3 : AUDIO IN
Pin4 : GND
Pin.5 : ALARM Out
Pin 6 : GND
Pin 7 : ALARM IN( IP Only)
Pin 8 : GND
Analog Connections Refer to previous figure.
1. Connect the power cable to the 2-postion terminal block. The camera accepts 24 VAC or 12 VDC
and polarity is not relevant.
2. Connect the coaxial cable for video output to the BNC connector.
3. To adjust the intensity of the LED illuminators, use the slide switch.
4. Connect the device to the AO (Alarm Out) and G (Ground) terminal block connectors. Alarm Out
can activate external devices such as buzzers or lights. There is no AI (Alarm In). Connect the
Audio In and Out as needed. Pinouts for the terminal block are printed on the board. Refer to
figure above.