Specifications

Page 40 of 61
SPECIFICATIONS (CONTINUED)
8. The VMS software shall provide Authorization rights setup for users for an administrator using
the Site Authorization screen. Group rights shall be configurable by specific site. VMDC users
shall be granted certain rights and access or full control based on their individual requirements.
9. The VMDC Main Window shall provide the following:
a. The Site and Device list depicting all DVRs, video encoders and IP cameras connected to the
local VMDC. The Site and Device list shall provide a physical list of all known network
sites and connected cameras, PTZ cameras and microphones. The cameras, PTZ cameras
and microphones shall be represented by graphical symbols.
b. Within the Site and Device list, each unit shall be depicted with all connected devices such
as: cameras connected (differentiating between PTZ and fixed cameras) and microphones.
c. The number of segments each monitor is displaying: 1, 4, 9, 16, 25, 36 or 64.
d. Components in the Site and Device list shall be selectable and configurable.
e. When a PTZ dome camera is selected, an operator shall be able to:
Control pan, tilt, zoom, iris and focus, including autoiris and autopan.
Program preset positions.
Execute preset positions.
Complete programming of menus embedded in the selected dome.
f. All PTZ programming and control shall be achieved remotely without requiring an operator
to be present at the recorder where the PTZ camera is connected.
g. PTZ control shall be performed dynamically onscreen, and not require an operator to click
on arrows to move the PTZ camera.
h. The PTZ control shall be fully variable by dynamically moving the cursor across the video
display.
i. The PTZ interface shall control all operation and programming functions of Vicon SVFT
domes and basic functions of PTZ domes by other manufacturers.
j. Access to all available programming menus.
k. Access to external controls, and reports for Alarm History, Audit Log and CFN log.
10. Viewing of live cameras shall be performed by:
a. Clicking on the monitor display location and then the desired camera in the Site and Device
list.
b. “Drag-and-Drop” from the Site and Device list to the location in the Monitor Display
Layout.
c. The software shall permit viewing of live video from any camera connected to the system.
d. The software shall support on-demand recording (manual recording) to a remote location.
e. The software shall support playback from the Main Window in the following formats:
Quick playback the user shall be able to select and launch playback for ViconNet®
encoded cameras in a pre-defined number of seconds before the live image. The
playback window shall open in the selected monitor location.
Playback from time shall allow setting the playback to start from a specific date, time
and database on the network. This shall allow playing back the same camera several
times.
11. Access to programming and more advanced screens shall be done by means of an immobile,
permanently docked toolbar located on the top live screen. The toolbar shall provide access to the
following major functionality of the system: