g. Send an email, text message, start video or any other task that can be initiated by a batch file
in response to a Central Failure Notification (CFN) or Recording System Verification (RVS)
notification.
h. An authorized user shall be able to program and execute macros remotely without the need
to be physically located at the recorder that the macros will be programmed on.
i. The Schedule/Macro button shall allow the running of preconfigured combinations of camera
and sensor routines.
j. Macro scheduling shall include but is not limited to:
i. Days of the week when a macro is active.
ii. Start and end time for when a macro is active.
iii. If a macro is to run continuously or not.
iv. A macro shall be able to run every:
v. 5 min, 10 min, 1/4 hour, 1/2 hour, 3/4 hour, 1 hour, 2 hours, 3 hours, 4 hours, 6
hours, 8 hours, 12 hours.
vi. A macro shall be able to be scheduled to run for 1-256 cycles.
9. The network and sites configuration shall allow:
a. Set up of a System Nucleus and Backup Nucleus. The Backup Nucleus shall maintain an
updated backup of all System Nucleus settings for recovery in case of failure. The system
shall provide failover and redundancy and be fully operational in the event of a System
Nucleus failure. Each device shall have an updated backup table to allow operation should
the System Nucleus fail. A Network Settings menu shall provide a comprehensive worksheet
for each networked device. When all units have been set up, the resulting connected devices
shall define the site.
b. Site Authorization: Workstation shall be set up using remote recorder or workstation GUI.
Site name and authorization shall be established by User and Group. Permissions shall be
assigned for all system functions.
c. Time synchronization of all components on the network.
d. All appropriate networking features including each server IP, Subnet and Gateway.
10. Device configuration shall have the ability to be configured for system recognition and operation.
Valid devices shall be:
a. Cameras
b. Sensors
c. Relays
11. All devices shall be assigned a unique ID number and title descriptor.
12. There shall be a Recording Verification System used to identify and log any recording errors
encountered during normal system operation. The log shall be manually reviewed for possible
video segment errors earmarked with a Recording Site, Device Name, Date/Time, Verified Site,
Macro Name and Error Description stamp. There shall be a Central Failure Notification (CFN)
System used to identify all possible site errors. The CFN shall be accessible from only the
Nucleus unit. The log shall be in a time/date order and be manually reviewed for errors.
13. There shall be a Site Map feature. It shall allow the installation and configuration of a custom
screen map used to identify and access site-installed components (cameras). The map should
include text boxes and sub-maps that further define the layout. This utility shall provide full
installation, configuration and editing of maps. Maps should have the ability to be moveable
anywhere on the screen.