Product specifications

4 Installation XX211-20 Rev 610 V15CCM-IR-2 Series High-Security Cell Cameras
Cable Connections
All cabling is done to the boards located on the back of the front plate.
Note: Vicon systems and components, like most electronic equipment, require a clean, stable power source.
Voltage irregularities such as surges, drops, and interruptions can affect the operation of your
equipment and, in severe cases, damage certain components.
Analog Cable Connections
1. Connect the power cable to the 2-postion terminal block TB1. The camera accepts 24 VAC and polarity is
not relevant.
2. Connect the coaxial cable for video output to the BNC connector (SK4).
3. To adjust the intensity of the LED illuminators, use RV1. Intensity can be adjusted over a range of
approximately 10:1 and is at maximum when RV1 is turned fully clockwise. The factory setting is for
maximum intensity.
IP Cable Connections
1. Use the RJ-45 connector if powering the camera using PoE. If using 24 VAC, connect the power cable to
the 2-postion terminal block.
2. Video and data are transmitted via the RJ-45 connector.
3. To adjust the intensity of the LED illuminators, use RV1. Intensity can be adjusted over a range of
approximately 10:1 and is at maximum when RV1 is turned fully clockwise. The factory setting is for
maximum intensity.
Final Installation
When all connections are made, secure the front plate to the base plate using the security screws previously
removed using no. 20 Torx bit.
Camera/Lens Positioning and Adjustments
The camera is on an adjustable mount so that it can be tilted slightly up and down to give a precise view. The
wide angle 2.5 mm lens enables the camera to view the area with no “blind spots.” Other camera/lens
adjustments are done through the OSD menu. The front plate includes a secure access plate that covers two
connectors, an RJ-45 and a BNC. The RJ-45 connector is used to connect a V15CC-PK hand-help keypad;
the BNC is connected to a monitor to view the programming menus.
1. Remove the two (2) screws securing the access plate with the no. 10 Torx bit.
2. Connect the keypad to the RJ-45 connector. Connect a monitor to the BNC and apply power to it.
3. On the keypad, press the SET key. The menu options display. Follow the menu system as described as
follows. Use the Up, Down, Right, Left keys to navigate the menus.