Product specifications

XX211-20 Rev 610 V15CCM-IR-2 Series High-Security Cell Cameras Installation 3
Installation
The wall/ceiling material must provide suitable strength to support the weight of the unit (3.5 lb/1.6 kg). Be
sure the area around the selected location is clear of obstacles (such as steel beams, headers, pipes,
electrical wiring, etc.) that would interfere with mounting. All cables must be routed to the installation location.
Verify that the accessory pack contains the items listed in Table 2.
Item Quantity Function
No. 20 Torx Bit 1 Use to remove and install tamperproof
screws from front plate
No. 10 Torx Bit 1 Use to remove and install tamperproof
screws from front plate access cover plate
2-Pin Terminal Block 1 Use to make power cable connections
Quick Guide/Documentation CD/
ViconNet CD (IP versions)
1 Installation and operation instructions;
ViconNet setup CD
Table 2: Accessory Kit
Mounting the Housing
The housing consists of two main assemblies, the base plate and the removable front plate, where the
camera and all electronics are mounted. The front plate is secured to the base plate with Resistorx
tamperproof screws. A special bit is supplied in the accessory pack for removing and replacing these screws.
When the installation is complete, retain the Torx bit in case access to the interior of the housing is required
later. Refer to Figure 1 as needed.
1. Remove the front plate using the no. 20 Torx bit provided; retain the screws in a safe place. Using the
base plate as a template, mark the locations of the mounting holes on the three mounting tabs (2 holes
per tab). Open a hole in the wall or ceiling to accommodate routing the cables to the camera.
2. Route all necessary cables to the location if not already done so.
3. Drill suitable holes for the hardware selected appropriate for the wall/ceiling material. The use of No. 8 (or
4 mm metric) mounting hardware is recommended. Use hollow-wall anchors or, if the housing is being
mounted on a sheet metal surface, use rivet nuts.
4. Secure the base plate to the wall/ceiling with fasteners appropriate for the mounting surface. Route the
cables through the access hole in the wall or ceiling.
5. When the base plate is secured to the surface, apply an epoxy security sealant around the perimeter of
the base plate where it meets the ceiling/wall. [Vicon recommends DynaPoxy™ EP1200 (US) or Arbokol
1025 (UK) or equivalent for this purpose.]