XX074-03 MODEL V1411X-DVC, V1411J-DVC AND V1410X-DVC VARIABLE-SPEED KEYPADS VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788 TEL: 631-952-CCTV (2288) FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116 24-Hour Technical Support: 800-34-VICON (800-348-4266) UK: +44 (0) 1489 566300 WEB: www.vicon-cctv.
FCC Notice Note: Complies with Federal Communications Commission Rules & Regulations Part 15, Subpart B for a Class A digital device. WARNING This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instruction, may cause interference to radio and television reception.
Important Safeguards GRAPHIC SYMBOL EXPLANATION 12. Power Cord Protection - Power supply cords should not be routed in trafficked areas or in tight spaces where they will be pinched or used to bear weight. Allow some slack in the cord where it enters the unit. 13. Outdoor Cable Grounding - Use only grounded outdoor cables to protect against voltage surges and static charges.
Contents Introduction .........................................................................................................................1 Configuration & Installation ...............................................................................................2 Passcode Setup...................................................................................................................8 Keypad Setup .................................................................................................
Introduction Note: Read all of the instructions completely before installing or operating this equipment. The information in this manual covers installation, programming and operation for the V1411X-DVC VariableSpeed Keypad and two alternate configurations, the V1411J-DVC and V1410X-DVC. The installation procedures should only be performed by a qualified technician using approved materials in accordance with national, state and local wiring codes.
Configuration & Installation Warning: Do not connect this unit to a power source until all connections are complete. In the installation figures that follow, the V1411X-DVC is shown. The figures are applicable to all three variations of the keypad (V1411X-DVC, V1411J-DVC and V1410X-DVC). The keypad is shipped with the following accessories: • RJ-45 termination box and RJ-45 cable • Power supply.
NOVA/Pilot To use any of Vicon’s Pilot/NOVA control systems with the keypad, you will use NOVA configuration. You may connect multiple keypads in this configuration, as shown in the example below. The keypad is shipped with a 12 VDC power supply for 120 VAC units and a 9 VAC power supply for 230 VAC units. One power supply is required for each keypad in your system. Only the first keypad shows a power supply in the figure below.
You can also daisy chain keypads as shown below. Connect all like signals; for example, connect Command In + on the first keypad’s RJ-45 box to Command In + on the second keypad’s termination box and so forth.
ViconNet System This section provides detailed connection methods for Kollector and VN-NVR PTZ controller connection only. The PTZ (joystick) portion of the keypad can be used to provide PTZ control of local and networked cameras in the system. NOTE: The other function buttons on the keypad are not supported by the driver of the Kollector or VN-NVR unit. A keypad can be directly connected to a Kollector Elite or VN-NVR unit. An RS-422 port or Serial (RS-232) to RS-422 converter is required for connection.
Installation Guideline 1. With the Kollector or VN-NVR unit ready for PTZ controller installation, locate and install the keypad in its permanent position, whether rack- or desk-mounted. 2. Locate and install the V422-CONV converter into the back panel. 3. Make all cable connections between keypad and back panel as shown in the Figure. If using the converter, verify that the correct polarity is maintained on the terminal block connections. 4.
ViconNet Setup ● The Baud Rate and COM Address (9600 and 4 in screen example below) in ViconNet and the keypad should match. NOTE: COM address can be any address 1-64. When setting address, make sure it does not conflict with a camera PTZ address. nd ● For the 2 generation KE back panels: Under Port COM 1 must be selected. st ● For the 1 generation KE back panels: Under Port COM 2 must be selected. ● For the VN-NVR back panel: Under Port COM 1 must be selected.
Passcode Setup You may use passcodes to limit use of the keypad. Eleven passcodes are permitted, one for a manager and ten users. The manager has access to all functions and setup parameters, including passcode setup. Only the manager may setup the keypad using mode 4, which is discussed in the next chapter. Note: From the factory, passcodes are disabled and the keypad can be immediately accessed. The manager passcode must be set up in order to have user passcodes. The manager passcode is always passcode 1.
Note: If an alarm occurs when there is no user logged on to a passcoded keypad, the passcode line of the display shown above will alternate between Passcode? ---- and Alarm. Enter a valid passcode and acknowledge the alarm as discussed on page Error! Bookmark not defined.. To manually log off of the keypad, perform the following keystrokes To automatically log off of the system, set a log off time as discussed in the next chapter. You must be a manager to set the auto log off time.
Setup Parameter Display Contrast Address Description Sets the LCD contrast. Sets the address for this keypad. Baud Rate Sets the communication baud rate. All keypads in your Pilot/NOVA/ViconNet system must have the same baud rate! Determines the communications timeout in milliseconds for single keypad operation only. Turns sound ON or OFF.
Operation Operating Modes If passcodes are not active, mode 1 is automatically entered after power is applied or if the keypad is reset. If passcodes are active, the passcode entry screen will display upon applied power or if the keypad is reset. Refer to Indicators in Display in the Technical Information chapter for LCD status messages. Alarms Note: The procedure to clear all alarms is applicable for V1500 systems only.
Communication Failure Note: The procedure to clear all failure announcements is applicable for V1500 systems only. Crosspoint Reset Note: To do a crosspoint reset, enter Dwell Mode (mode 3) and set 9999 or 9900 followed by A/P. Refer to Accessing Operating Modes on previous page for how to enter Dwell Mode. Lens Operation Presets Preset recall allows you to return to a pre-defined pan-and-tilt position (and zoom/focus settings, if the camera includes a motorized zoom lens).
Manual Switching Salvos and Tours Note: Salvos and tours are not available in all control systems. Refer to your control system documentation if necessary. Sequential Switching Note: Sequential switching is not available in all control systems. Refer to your control system documentation if necessary.
Using the Joystick 14 • Operation XX074-03-00 Rev 208 Variable-Speed Keypad
Technical Information PrePac Model Descriptions Model Number Product Code V1411X-DVC 7518 V1411X-DVC-230 7518-01 V1411J-DVC 7832 V1411J-DVC-230 7832-01 V1410X-DVC 7847 V1410X-DVC-230 7847-01 Input Voltage 120 VAC 230 VAC 120 VAC 230 VAC 120 VAC 230 VAC Power Supply 12 VDC at 500 mA. 9 VAC at 600 mA. 12 VDC at 500 mA. 9 VAC at 600 mA. 12 VDC at 500 mA. 9 VAC at 600 mA. Electrical Input Voltage: Fuse: Communications: Cabling: See PrePac Model Descriptions above. Note that you may also use a 9.
Mechanical V1411X-DVC and V1411X-DVC-230: Construction: Zinc plated steel. Finish: Black “walnut”. Dimensions: Height: 2.25 in. (57 mm). Width: 11.5 in. (292 mm). Depth: 6.9 in. (175 mm). Weight: 3.0 lb (1.4 kg). V1411J-DVC and V1411J-DVC-230: Construction: Zinc plated steel. Finish: Black “walnut”. Dimensions: Height: 3.0 in. (75 mm). Width: 11.5 in. (292 mm). Depth: 6.9 in. (175 mm). Weight: 3.0 lb (1.4 kg). Shipping Instructions Use the following procedure when returning a unit to the factory: 1.
Vicon Standard Equipment Warranty Vicon Industries Inc. (the “Company”) warrants your equipment to be free from defects in material and workmanship under Normal Use from the date of original retail purchase for a period of three years, with the following exceptions: 1. 2. 3. 4. 5. VCRs, all models: Labor and video heads warranted for 120 days from date of original retail purchase. All other parts warranted for one year from date of original retail purchase.
Vicon Industries Inc.